OM/SM-HY-12GF(CE) & HY-24GF(CE) 23
OM/SM-HY-12GF(CE) & HY-24GF(CE)
23
2.1.34 Door Locking Pin
- P/N
078914
Door Pin Lock Nut -
P/N
003823
1. Turn off power and allow steamer to cool.
2. Record the distance between the lock nut and
the end of the (bullet shaped) locking pin. This
information will be needed for installation.
3. Loosen the lock nut using a ½ inch box wrench.
Remove the lock nut and door pin.
To Install:
4. Coat bullet threads with Never-Seez high temp
(1000ºC) anti-seize and lubricating compound.
5. Install locking pin and lock nut. The lock nut to
end-of-pin distance should be the same as
measured in Step 2.
6. The pin should be set to retain the closed door
firmly.
7. Frictional force is adjusted by turning the door
pin in or out, accordingly.
8. Adjust pressure so that a banknote or similar
piece of paper, when grasped by the thumb and
forefinger, may be pulled out with a slight effort.
9. Remove screws. Remove handle from cam.
10. Apply Never-Seez high temperature (1000ºC)
anti-seize and lubricating compound to the cam,
and Locktite 242 to the screw threads.
11. Turn handle and cam 180-degrees from original
positions and install on the door with screws. Be
sure handle and cam move smoothly.
12. Be sure the door handle is DOWN. Turn U-
channel 180-degrees from its original position.
Hold the door spring in the U-channel open with
a screwdriver, and install the U-channel.
13. Check the cam operation. Push up on the door
handle and see if the spring opens. If it does not,
the cam and spring are NOT correctly aligned
and the problem must be corrected.
14. Apply a light amount of Locktite 242 to the
screws, then install them.
15. Apply Locktite 242 to the hinge-to-steamer bolts.
Install the door and hinge mounting bolts. Do
NOT tighten mounting bolts at this time.
16. Align the door to steamer. Refer to 2.1.28.
17.
IMPORTANT
: When door is reversed, the
alternate door switch (installed at the time of
manufacture) must be connected to the circuit.
18. From the right side access of the upper part of
steamer, disconnect the two door switch leads.
19. Wires for the alternate door switch are between
the upper and lower cavities. Connect the two
wires from the switch to the wiring harness.
20. Close steamer and operate five minutes. Then
check for leaks. If there are no leaks, the
steamer is ready for operation. If there are leaks
around the door, recheck door alignment, and if
necessary, door gasket installation.
Summary of Contents for HY-12GF(CE)
Page 24: ...24 OM SM HY 12GF CE HY 24GF CE 24 2 2 Parts Identification...
Page 26: ...26 OM SM HY 12GF CE HY 24GF CE OM SM HY 12GF CE HY 24GF CE 2 2 Parts Identification...
Page 27: ...OM SM HY 12GF CE HY 24GF CE 27 OM SM HY 12GF CE HY 24GF CE 2 2 Parts Identification...
Page 31: ...OM SM HY 12GF CE HY 24GF CE 31 OM SM HY 12GF CE HY 24GF CE Electrical Schematic...
Page 41: ...OM SM HY 12GF CE HY 24GF CE 41...
Page 47: ......