OM-HY-12E/24E
8
Installation of drain line without drain box
(tabletop models only).
Drain Connection with Drain Box (All units are
shipped from the factory with a drain box).
Old
model shown.
3. Drain Connection
The HY-12E/24E Steamer must be leveled front to
back or pitched slightly to the rear by adjustment of
the bullet feet on the cabinet base.
All units are shipped from the factory with a drain
box and vent pipe. The drain box and vent pipe
provide the necessary air gap when properly
installed. The illustrations below show proper
installation of drain lines from the drain box, and for
tabletop installation, without a drain box.
CAUTION
DO NOT CONNECT THE HOSE DIRECTLY TO
A BUILDING DRAIN. BLOCKING THE DRAIN
COULD BE DANGEROUS.
Do not create any water traps in the drain line. A
trap would cause pressure to build up inside the
cavity during steaming and make the door gasket
leak.
NOTE:
Improper drain connection will void the
warranty.
INSTALLATION OPTION ONE:
From stainless steel
elbow (P/N 092273) to nearby floor drain, use Radiator
Hose (rated at least 212ºF) and one additional hose
clamp (P/N 013616).
INSTALLATION OPTION TWO:
Using the hose (P/N
080688) and two hose clamps (P/N 013616), connect
two inch copper tube to floor
drain. NOTE:
Drain lines
must be pitched downward at approximately inc h per
foot. No water traps should be allowed in the drain line.
IMPORTANT:
Leave two inches free air gap to
building drain.
8
OM-HY-12E/24E