background image

OM-HH

23

Limited Warranty

To Commercial Purchasers *

(Domestic U.S., Hawaii & 
Canadian Sales Only)

Groen Foodservice Equipment ("Groen Equipment") has been skillfully manufactured, carefully inspected and
packaged to meet rigid standards of excellence. Groen warrants its Equipment to be free from defects in
material  and  workmanship for (12) twelve months with the following conditions and subject to the following
limitations.

I.

This  parts  and  labor  warranty is limited to Groen Equipment sold to the original commercial
purchaser/users (but not original equipment manufacturers), at its original place of installation in the
continental United States, Hawaii and Canada.

II.

Damage during shipment is to be reported to the carrier, is not covered under this warranty, and is
the sole responsibility of purchaser/user.

III.

Groen,  or  an  authorized  service  representative, will repair or replace, at Groen's sole election, any
Groen  Equipment,  including but not limited to, drawoff valves, safety valves, gas and electric
components, found to be defective during the warranty period.  As to warranty service in the territory
described above, Groen will absorb labor and portal to portal transportation costs (time & mileage)
for the first twelve (12) months from date of installation or fifteen (15) months from date of shipment
from Groen.

IV.

This warranty does not cover boiler maintenance, calibration, periodic adjustments as specified in
operating instructions or manuals, and consumable parts such as scraper blades, gaskets, packing,
etc.,  or  labor costs incurred for removal of adjacent equipment or objects to gain access to Groen
Equipment. This warranty does not cover defects caused by improper installation, abuse, careless
operation, or improper maintenance of equipment.  This warranty does not cover damage caused by
poor water quality or improper boiler maintenance.

V.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED
OR  IMPLIED,  INCLUDING  ANY  IMPLIED  WARRANTY  OF  MERCHANTABILITY  OR  FITNESS
FOR  A  PARTICULAR  PURPOSE, EACH OF WHICH IS HEREBY EXPRESSLY DISCLAIMED.
THE REMEDIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN NO EVENT SHALL GROEN BE
LIABLE FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR THE BREACH OR
DELAY IN PERFORMANCE OF THIS WARRANTY.

VI.

Groen  Equipment  is for commercial use only. If sold as a component of another (O.E.M.)
manufacturer's  equipment,  or  if  used  as  a  consumer product, such Equipment is sold AS IS and
without any warranty.

* (Covers All Foodservice Equipment Ordered After October 1, 1995)

Summary of Contents for HH/4

Page 1: ...AMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVEN USER SMELLS GAS THIS INFORMA TION SHALL BE OBTAINED BY CO...

Page 2: ...SOLUTIONS OUT OF CONTROLS AND BURNERS NEVER SPRAY OR HOSE CONTROL CONSOLE ELECTRICAL CONNECTIONS ETC CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING PRECAUTIONS SHOUL...

Page 3: ...ences KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Minnesota 55102 800 352 5326 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA 70 Th...

Page 4: ...uum gauge shows the steam pressure and if there is air in the jacket Indicator lamp Lights when the kettle is being heated Automatic controls within the unit Gas Pressure Regulator Adjusts gas pressur...

Page 5: ...rk Capacity gallons liters 40 150 40 150 Rim Height inches mm 38 960 38 960 Depth inches mm 22 560 22 560 Diameter inches mm 26 660 26 660 Overall front to back inches mm 40 1030 40 1030 Firing Rate B...

Page 6: ...mage Report any shipping damage or incorrect shipments to the delivery agent Write down the model number serial number and installation date and retain this information for future reference Space for...

Page 7: ...ange must be approved by the Groen Food Service Engineering Department WARNING DO NOT ATTACH THE UNIT TO A TYPE B VENT FAILURE COULD RESULT IN A FIRE AND OR PROPERTY DAMAGE Install the unit under a ve...

Page 8: ...s piping system at pressures equal to or less than PSI 3 48 kPa 15 Check the following points to confirm that your HH kettle has been installed properly a Sufficient room between the kettle and nearby...

Page 9: ...ection of this manual for the location of controls and other features B Operating Procedure WARNING KEEP KETTLE AREA FREE AND CLEAR OF ALL COMBUSTIBLE MATERIALS 1 To Start Kettle a CHECK THE WATER LEV...

Page 10: ...e a The kettle is emptied by means of its draw off valve by ladling product out or using the optional TRI BC Cooking Basket Set WARNING OPEN THE KETTLE LID CAREFULLY TO AVOID STEAM DIRECT CONTACT WITH...

Page 11: ...witch ON supplies electric power to the thermostat Turning the dial to an operating setting closes the thermostat switch and energizes the gas control Simultaneously an arc is established at the spark...

Page 12: ...b Also check the jacket water level every day It should be between the marks on the gauge glass If the level is low see Jacket Filling and Water Treatment on page 13 c Test the safety valve at least...

Page 13: ...lug from the jacket fill assembly c Open the gate valve and pour in the distilled or treated water d Hold the safety valve open to allow air to escape from the jacket while you pour in the water Conti...

Page 14: ...NER LABEL DIRECTIONS CAREFULLY 3 Procedure a Clean food contact surfaces as soon as possible after use If the unit is in continuous use thoroughly clean and sanitize the interior and exterior at least...

Page 15: ...nd drain the unit before further use m If cleaning problems persist contact your cleaning product representative for assistance The supplier has a trained technical staff with laboratory facilities to...

Page 16: ...er a Procedure See Operation section of this manual Auth Service Rep Only b Pilot tubing and orifice for clogging Y c That pilot gas supply line is purged of air Y d Gas pressure at the automatic valv...

Page 17: ...4 V between terminals 3 and GR If voltage is not correct replace the ignition control Y b That the gas pressure meets the control manufacturer s specifications Y c Electrical connections of the main v...

Page 18: ...OM HH 4 Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable voltage and phase...

Page 19: ...Valve 002484 19 Water Fill Assy Built before 8 1 92 013541 51 Gauge Glass Connector 004071 Water Fill Assy Built after 8 1 92 097010 52 Rubber Gauge Glass Gasket 008917 20 Safety Valve Built before 8...

Page 20: ...OM HH 20 HH 4 Standing Pilot Ignition HH 4E Spark Ignition Type QHL 1 Wiring Diagrams...

Page 21: ...OM HH 21 HH 4E Spark Ignition Type G96 HH 4E Spark Ignition Type CCG Electrical Schematics...

Page 22: ...______ Serial No _______________________________ Location ________________________________ Date Purchased __________________________ Date Installed ___________________________ Purchase Order No ______...

Page 23: ...ortal transportation costs time mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boiler maintenanc...

Page 24: ...1055 Mendell Davis Drive Jackson Mississippi 39212 Telephone 601 373 3903 FAX 601 373 9587 OM HH Revised 10 98 Part Number 121034...

Reviews: