background image

OM-HH

19

Parts List

Key

Description

Part No.

Key

Description

Part No.

1

¼”-20 Cap Nut

005471

37

Removable Strainer 

c

” holes

009040

2

Handle Assy (includes items 3 & 4)

047714

for optional 1½” Draw-Off

3

Knob

012691

Removable Strainer 

c

” holes

013785

4

Spacer

002378

for standard 2” Draw-Off

5

Hinge Bar

061012

38

Strainer w/o holes for 1½” Draw-Off

009057

6

Cover Hinge Bracket

013485

Strainer w/o holes for 2” Draw-Off

013783

7

Tolerance Ring

012692

39

Gas Pilot Burner

002457

8

Indicator Light Assembly

002986

40

¾” Gas Valve (built after 11/88) 

097001

9

¾” IPS x 4½“ Nipple

005560

¾’ Gas Valve (built before 12/88)

002487

10

¼” IPS Gas Valve

002485

41

Hinge Cover LH (Prior to 5/10/84)

002293

11

Pressure Gauge

099156

42

Half Hinge LH (Prior to 5/10/84)

012878

12

Warrick Electrode

074665

43

¾” IPS St. El

009347

13

Rubber Boot

010390

44

¾” x ¼” x ¾” Reducing Tee

008716

14

Pressure Limit Control

096963

45

¾” IPS x 3½” Long Nipple

008716

15

Thermostat

012313

46

¾” 90 Degree El

008124

16

Thermostat Knob

012314

47

¾” x 3" Long IPS Nipple

008239

17

Flue Assy Box, HH Kettles

004951

48

Gas Pressure Regulator

101570a

18

¾” IPS 90º El (Built before 8/1/92)

010668

49

¾” x 2½” Long Nipple

005559

¾” IPS 90º El (Built after 8/1/92)

096905

50

¾” Gas Valve

002484

19

Water Fill Assy (Built before 8/1/92)

013541

51

½” Gauge Glass Connector

004071

Water Fill Assy (Built after 8/1/92)

097010

52

Rubber Gauge Glass Gasket

008917

20

Safety Valve (Built before 8/1/92)

004010

53

Washer w/Assy #4071

N/A

Safety Valve (Built after 8/1/92)

097009

54

Hex Nut w/Assy #4071

N/A

21

Not Used

N/A

55

Water Gauge Glass

008742

22

Not Used

N/A

56

Not Used

N/A

23

Toggle Switch

006904

57

Gas Valve (Prior to 6/89)

N/A

24

Warrick Relay (115 Volt)

010412

Gas Valve (Built after 5/89)

079803

25

Wing Nut #10-24

009028

58

Close Nipple ½” IPS

008877

26

Valve Handle

009029

59

Reducing El ¾” x ½” x 90 Degrees

008751

27

Sanitary Hex Nut #1314

008911

60

Nipple ¾” IPS x 4" Long

005523

28

Rubber “O” Ring

009034

61

Union Elbow ¾” IPS x 4" Long

005493

29

Valve Bonnet

009024

62

Sensing Probe w/Kanthol

003328

30

Valve Stem

009027

63

Not Used

N/A

31

Optional 1½” Draw-Off Valve

009000

64

Nipple ¾” IPS x 4" Long

005523

32

Burner with Jets

004825

65

¾” IPS Gas Valve

008172

33

Slotted Cap for Item 32 (not shown) 004826

66

Pilot Burner and Electrode

003750

34

Not Used

N/A

67

Sensing Probe Lead

003329

35

Not Used

N/A

68

Half Hinge RH (prior to 5/10/84)

012877

36

Removable Strainer ¼” holes

009007

69

Hinge Cover RH  (prior to 5/10/84)

002292

for optional 1½” Draw-Off

70

Not Used

N/A

Removable Strainer ¼” holes

009044

71

Union ¾” IPS

005516

for standard 2" Draw-Off

NOTE: HH/4 and HH/4/E use natural gas only.

Summary of Contents for HH/4

Page 1: ...AMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVEN USER SMELLS GAS THIS INFORMA TION SHALL BE OBTAINED BY CO...

Page 2: ...SOLUTIONS OUT OF CONTROLS AND BURNERS NEVER SPRAY OR HOSE CONTROL CONSOLE ELECTRICAL CONNECTIONS ETC CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING PRECAUTIONS SHOUL...

Page 3: ...ences KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Minnesota 55102 800 352 5326 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA 70 Th...

Page 4: ...uum gauge shows the steam pressure and if there is air in the jacket Indicator lamp Lights when the kettle is being heated Automatic controls within the unit Gas Pressure Regulator Adjusts gas pressur...

Page 5: ...rk Capacity gallons liters 40 150 40 150 Rim Height inches mm 38 960 38 960 Depth inches mm 22 560 22 560 Diameter inches mm 26 660 26 660 Overall front to back inches mm 40 1030 40 1030 Firing Rate B...

Page 6: ...mage Report any shipping damage or incorrect shipments to the delivery agent Write down the model number serial number and installation date and retain this information for future reference Space for...

Page 7: ...ange must be approved by the Groen Food Service Engineering Department WARNING DO NOT ATTACH THE UNIT TO A TYPE B VENT FAILURE COULD RESULT IN A FIRE AND OR PROPERTY DAMAGE Install the unit under a ve...

Page 8: ...s piping system at pressures equal to or less than PSI 3 48 kPa 15 Check the following points to confirm that your HH kettle has been installed properly a Sufficient room between the kettle and nearby...

Page 9: ...ection of this manual for the location of controls and other features B Operating Procedure WARNING KEEP KETTLE AREA FREE AND CLEAR OF ALL COMBUSTIBLE MATERIALS 1 To Start Kettle a CHECK THE WATER LEV...

Page 10: ...e a The kettle is emptied by means of its draw off valve by ladling product out or using the optional TRI BC Cooking Basket Set WARNING OPEN THE KETTLE LID CAREFULLY TO AVOID STEAM DIRECT CONTACT WITH...

Page 11: ...witch ON supplies electric power to the thermostat Turning the dial to an operating setting closes the thermostat switch and energizes the gas control Simultaneously an arc is established at the spark...

Page 12: ...b Also check the jacket water level every day It should be between the marks on the gauge glass If the level is low see Jacket Filling and Water Treatment on page 13 c Test the safety valve at least...

Page 13: ...lug from the jacket fill assembly c Open the gate valve and pour in the distilled or treated water d Hold the safety valve open to allow air to escape from the jacket while you pour in the water Conti...

Page 14: ...NER LABEL DIRECTIONS CAREFULLY 3 Procedure a Clean food contact surfaces as soon as possible after use If the unit is in continuous use thoroughly clean and sanitize the interior and exterior at least...

Page 15: ...nd drain the unit before further use m If cleaning problems persist contact your cleaning product representative for assistance The supplier has a trained technical staff with laboratory facilities to...

Page 16: ...er a Procedure See Operation section of this manual Auth Service Rep Only b Pilot tubing and orifice for clogging Y c That pilot gas supply line is purged of air Y d Gas pressure at the automatic valv...

Page 17: ...4 V between terminals 3 and GR If voltage is not correct replace the ignition control Y b That the gas pressure meets the control manufacturer s specifications Y c Electrical connections of the main v...

Page 18: ...OM HH 4 Parts List To order parts contact your Groen Certified Service Agency Supply the model designation part description part number quantity and where applicable voltage and phase...

Page 19: ...Valve 002484 19 Water Fill Assy Built before 8 1 92 013541 51 Gauge Glass Connector 004071 Water Fill Assy Built after 8 1 92 097010 52 Rubber Gauge Glass Gasket 008917 20 Safety Valve Built before 8...

Page 20: ...OM HH 20 HH 4 Standing Pilot Ignition HH 4E Spark Ignition Type QHL 1 Wiring Diagrams...

Page 21: ...OM HH 21 HH 4E Spark Ignition Type G96 HH 4E Spark Ignition Type CCG Electrical Schematics...

Page 22: ...______ Serial No _______________________________ Location ________________________________ Date Purchased __________________________ Date Installed ___________________________ Purchase Order No ______...

Page 23: ...ortal transportation costs time mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boiler maintenanc...

Page 24: ...1055 Mendell Davis Drive Jackson Mississippi 39212 Telephone 601 373 3903 FAX 601 373 9587 OM HH Revised 10 98 Part Number 121034...

Reviews: