OM-CBE-10G 9
Installation
2. Electrical Supply Connection
Provide 115 VAC, 60 HZ, 1 PH, 15 AMP service. Bring wire in through hole in
the lower left back panel. Each cavity requires a separate cord for connections.
Local codes and/or the National Electrical Code should be observed in accordance
with ANSI/NFPA 70. AN ELECTRICAL GROUND IS REQUIRED. The wiring diagram
is located in the service compartment and in this manual. Maximum load is
12 AMPs. In Canada, provide electrical service in accordance with the Canadian
Electrical Code, CSA C22.1 Part 1 and/or local codes.
3. Gas Supply Connection
Connection to the gas supply shall be ½” NPT pipe size. Double stack units
require 2 separate gas connections.
NOTE:
For operation at high altitudes (2000’ and above), please consult Groen
Engineering Department.
In Canada, the installation must conform to the Canadian Gas Code, CAN 1-B1 49,
Installation Codes for Gas Burning Appliances and Equipment and/or local codes.
After the unit has been connected to the gas supply, all gas joints must be checked
for leaks.
Do NOT use flame checking for leaks.
A thick soap solution or other
suitable leak detector should be used.
Unit Restraining Requirement
A. The installation shall be made with a connector that complies with the
standard for connectors for movable gas appliances. ANSI Z21.69.CSA
6.16, and a quick-disconnect device that complies with the standard for
quick-disconnect devices for use with gas fuel, ANSI Z21.41.CSA 6.9.
B. Adequate means must be provided to limit the movement of the appliance
without depending on the connector and the quick-disconnect device or its
associated piping to limit the appliance movement.
C. The location where the restraining device may be attached to the appliance
shall be in accordance with Groen specifications for the device. (see photo)
CAUTION
THIS OVEN REQUIRES A 15 AMPERE OUTLET
AND CIRCUIT. TO PREVENT NUISANCE TRIP
OF CIRCUIT BREAKER, IT IS RECOMMENDED
THAT THE ELECTRICAL CIRCUIT SHOULD NOT
BE SHARED WITH OTHER APPLIANCES.
WARNING
FOR UNIT INSTALLED ON CUSTOMER
SUPPLIED STANDS, CASTERS ARE REQUIRED
WITH RESTRAINING REQUIREMENT AS LISTED.
Ratings for Gas Combination Oven
*Measured at gas manifold
BTU
*Operating
Pressure
MIN Incom-
ing Gas
Feed Rate
MAX In-
coming Gas
Feed Rate
CBE-10G-NG
75,000
3.50” WC
5” WC
14” WC
CBE-10G-LP
75,000
10.0” WC
12” WC
14” WC
Eyebolt connector on the back of the unit.