background image

14 

OM-CBE-10G

Operation

1.   To Light

A.   Open gas valve on rear left of unit.

B.  Push power switch to ON.  The display will show SELECT MODE and PRE-

HEATING.

C.   Select the desired operating mode.  If STEAM was pushed while PREHEATING 

was displayed the TEMPERATURE display will show three blinking dashes 

until the temperature rises above 230°F.

1.  For STEAM mode press the STEAM button.

a.  The STEAM indicator will light.  After that the display will show three 

steady  dashes  indicating  that  the  steaming  temperature  has  been 

reached (the ready condition).

2.  For OVEN mode press the OVEN button.

a.  The OVEN indicator lights.  Adjust the TEMPERATURE knob (the upper 

knob) for the desired cooking temperature; the lower limit is 200°F, 

the upper limit is 450°F.

3.  For COMBO mode press COMBO button.

a.  The  COMBO  and  LO  moisture  level  indicators  light.    Adjust  the 

TEMPERATURE  knob  (the  upper  knob)  for  the  desired  cooking 

temperature; the lower limit is 200°F, the upper limit is 450°F.  If the 

cavity temperature is more than 20°F below the selected temperature 

the  TEMPERATURE  display  flashes  until  the  temperature  is  within 

20°F of the selected temperature (this signals the ready condition).

b.  Push Moisture Level HI.  The two side reservoirs fill and the center 

reservoir empties.  The TEMPERATURE knob operates the same way 

as in COMBO LO except that the upper limit is reduced to 350°F.

c.  Select Fan Speed HI or LO by pressing Fan Speed HI or Fan Speed LO.

4.  In  either  OVEN  or  COMBO  mode,  pressing  the  CRISPEase

™ 

button 

increases moisture venting from the cavity and boosts oven heating by 

5000 BTU, while also draining reservoirs to eliminate additional moisture 

addition.

2.   To Re-Light

A.   Push power switch to OFF.  Wait 5 minutes, then repeat step 1.

3.   To Shut-Off

A.   Push power switch to OFF. 

B.  Close gas valve on rear left of unit.

CAUTION

WHEN THE UNIT IS MOVED FROM ITS ORIGINAL 
POSITION FOR ANY CLEANING OR SERVICE, THE 
HOOKS  ON  RESTRAINING  CABLE  ASSEMBLY 
MUST  BE  RECONNECTED  AT  BOTH  ENDS.  
DETAILED INSTRUCTONS FOR RE-CONNECTION 
TO  THE  APPLIANCE  ARE  SHOWN  UNDER 
“INSTALLATION” SECTION, ITEM 3.

Summary of Contents for (2) CBE-10G

Page 1: ...Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing o...

Page 2: ...EANING THE OUTSIDE OF THE UNIT DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING A...

Page 3: ...page 14 16 Sequence of Operation page 17 18 Maintenance page 19 Cleaning page 20 21 Service Log page 22 NATIONAL FIRE PROTECTION ASSOCIATION 60 Batterymarch Park Quincy Massachusetts 02269 NFPA 70 Th...

Page 4: ...d The optional stand must have casters Optional stands are available for single and double stack 2 high units The optional stand must have casters All units are intended to slide under a kitchen hood...

Page 5: ...mber and a drain box The unit is provided with two air and steam vents One is to prevent internal pressure build up This vent pipe exit is located at upper left corner of the unit just above the rear...

Page 6: ...ge from nails and sharp pieces of wood or staples which might be left in carton walls Writedownthemodelnumber serialnumberandinstallationdateandkeepthisinformation for future reference Space for these...

Page 7: ...atment system and a regular cartridge replacement schedule is essential 3 Using a Groen water treatment system will provide longer steam generator boiler life higher steam capacity and reduce maintena...

Page 8: ...strict the flow of air for combustion and ventilation must be removed Do not obstruct the flue cover or rear vents after installation THE AREA DIRECTLY AROUND THE APPLIANCE MUST BE CLEARED OF ALL COMB...

Page 9: ...ick soap solution or other suitable leak detector should be used Unit Restraining Requirement A The installation shall be made with a connector that complies with the standard for connectors for movab...

Page 10: ...o matter how slowly Do not over tighten hose connections COLD WATER PRESSURE 30 60 PSI SEE PAGE 6 FOR WATER TREATMENT REQUIREMENTS This equipment is to be installed to comply with the basic plumbing c...

Page 11: ...a single unit The units are stacked and assembled at the factory A Water Connection The same water supply connection is used for both units At the water inlet valve a inch female NH connector garden h...

Page 12: ...dy to cook within 25 minutes or less The ready condition is indicated as follows In oven mode Temperature display red LED will stop flashing In Hi or Lo combination mode Temperature display red LED wi...

Page 13: ...art timer count Time setting can not be readjusted higher or lower during the timing cycle Beeper sounds when the set time cycle is complete Push Cancel to stop the beeper Fan Speed Convection fan can...

Page 14: ...F the upper limit is 450 F If the cavity temperature is more than 20 F below the selected temperature the TEMPERATURE display flashes until the temperature is within 20 F of the selected temperature t...

Page 15: ...the cooking modes If oven is in any cooking mode press that mode button to deselect and go to stand by mode F To select clean mode press the CLEAN button G Follow the instructions on the display NOTE...

Page 16: ...IN CLEANING AND DELIMING INSTRUCTIONS 6 When the unit is to be disconnected from gas supply and moved for servicing and or cleaning the gas restraining cable hook must be disconnected first see Insta...

Page 17: ...combo and oven modes it is set by the user When the oven is not ready the word PREHEAT is displayed and the temperature display flashes Once the oven comes up to ready PREHEAT disappears and the tempe...

Page 18: ...d the CANCEL indicator flashes Push CANCEL to stop the beeper Note that this is all the timer does it is a simple kitchen timer It does not stop any cooking process it simply alerts the operator that...

Page 19: ...quid level probes with a non abrasive stiff brush Two 2 liquid level probes are located on the rear wall of the unit below the fan see photo C Open the inner glass panel and check the light assembly f...

Page 20: ...MODE RINSE TIME appears in the display to flush the cleaner off the cavity walls 8 This is followed by a drain period CLEAN MODE DRAIN TIME appears in the display followed by the rinse 9 When this is...

Page 21: ...and the display message changes to OPEN DOOR TO COOL OVEN 7 When the door is opened the display message changes to COOLING 8 When the oven has cooled sufficiently to allow it to continue the display...

Page 22: ...22 OM CBE 10G Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Page 23: ...OM CBE 10G 23 NOTES...

Page 24: ...REV D 12 10 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2010 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...

Reviews: