OM-CBE-10G
Installation
1. Installation
Minimum Clearances:
The Combination Oven requires the following minimum
clearances to any surface, combustible or non-combustible. Floor clearance is 6
inches minimum to bottom of frame.
Right Side
6 inches
Left Side
6 inches
Rear
0 inches for motor
Recommended Service Clearances:
Right Side
14 inches
Left Side
6 inches
Rear
24 inches
Front
36 inches
Steam Free Zone:
The Combination Oven can be damaged by steam from
external sources. Do not install the unit steam venting drain. Ensure that steam is
not present in an area bounded by the footprint of the unit and a circle 18 inches
in radius about the right and left rear corner of the unit (see figure to the left).
Install and operate the gas appliance in a well ventilated area. Adequate air must
be supplied to replenish the air used for combustion. Ventilation must employ a
vent hood and exhaust fan with no direct connection between the vent duct and
the combination oven flue. Installation must conform with local codes and/or with
the National Fuel Gas Code, ANSI Z223.1/NFPA-54 (latest edition) or the Natural
Gas and Propane Installation Code CSA B 149.1 as applicable.
Any item which might obstruct or restrict the flow of air for combustion and
ventilation must be removed. Do not obstruct the flue cover or rear vents after
installation.
THE AREA DIRECTLY AROUND THE APPLIANCE MUST BE CLEARED OF ALL
COMBUSTIBLE MATERIAL. FAILURE TO FOLLOW THESE INSTRUCTIONS CAN
CAUSE BODILY INJURY AND/OR PROPERTY DAMAGE.
NOTE:
The unit must be installed on a stand with casters.
The unit must be
disconnected
from the gas supply system during any pressure
testing of that system which has test pressures in excess of ½ psi (3.45 kPa).
The unit must be
isolated
from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at
test pressures equal to or less than ½ psi (3.5 kPa).
WARNING
THE UNIT MUST BE INSTALLED BY
PERSONNEL WHO ARE QUALIFIED TO WORK
WITH GAS, ELECTRICITY AND PLUMBING.
IMPROPER INSTALLATION CAN CAUSE
INJURY TO PERSONNEL AND/OR DAMAGE
TO THE EQUIPMENT. THE UNIT MUST
BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES. THE UNIT MUST BE
INSTALLED BY A LICENSED PLUMBER OR
GAS FITTER WHEN INSTALLED WITHIN THE
COMMONWEALTH OF MASSACHUSETTS.
CAUTION
DO NOT INSTALL THE UNIT WITH THE REAR
VENTS BLOCKED OR WITHIN 6 INCHES OF
A HEAT SOURCE SUCH AS A BRAISING PAN,
DEEP FAT FRYER, CHARBROILER OR KETTLE.
TO AVOID DRAINAGE PROBLEMS, LEVEL THE
UNIT AND PITCH IT SLIGHTLY TO THE REAR.
CBE -10G
(top view)
18 - inch
radius
18 - inch
radius
457 mm
457 mm