-24-
Model T28366 (Mfd. Since 04/18)
3. Remove arbor cap screw (see Figure 31).
It has left-hand threads and loosens when
turned clockwise.
4. Remove retaining ring from retractable guard
hub (see
Figure 32) to provide clearance to
remove/install blade. DO NOT remove plastic
bushing from hub.
Figure 32. Removing retaining ring.
Plastic
Bushing
Retaining
Ring
Figure 31. Removing arbor cap screw.
Retractable
Blade
Guard
Loosen
Cap
Screw
Retractable
Blade
Guard
Installing/Changing
Blades
Metal cutting blades should be checked
regularly for wear or damage to help ensure
operator safety and high-quality cutting results.
Always immediately replace any blade found with
damage.
Item(s)
Needed
Qty
New 10" Cold Cut Saw Blade ............................ 1
Hex Wrench 5mm .............................................. 1
Hex Wrench 8mm .............................................. 1
Retaining Ring Pliers ......................................... 1
To install/change blade:
1. DISCONNECT MACHINE FROM POWER!
2. Disconnect blade guard linkage by
removing cap screws connecting linkage to
base of column neck (see
Figure 30). This
releases tension on retractable blade guards
(see
Figure 31).
The teeth of saw blades are
sharp and can easily cut
fingers and hands. Always
wear heavy leather gloves
when handling saw blades.
Figure 30. Location of blade guard linkage and
cap screws.
Blade Guard
Linkage
Cap
Screws