G1028/G1029 Dust Collector
G1028 Wiring
The G1028 Dust Collector is pre-wired for 110V,
but can be rewired for 220V. Refer to the wiring
diagram included with this manual for instruction.
Do not attempt to rewire the motor if the diagram
is missing. Contact the appropriate service center
for more information.
A plug is not provided with the G1028. It will be
necessary to purchase a standard 110V plug
from your local hardware store. If you are rewiring
for 220V, see
Figure 1
for recommended 220V
receptacle.
Circuit Breaker:
The 1 HP motor will draw
roughly 13 amps @ 110V, 6 @ 220V. We recom-
mend a using 20 amp circuit breaker for 110V or
220V operation. Circuit breakers rated higher will
not adequately protect the motor. If you are using
a fuse, we recommend 30 amp slow blow for
110V or 220V operation. Fuses rated higher will
not adequately protect the motor.
SECTION 2: CIRCUIT REQUIREMENTS
G1029 Wiring
The G1029 Dust Collector is pre-wired for 220V
and cannot be rewired for 110V.
A plug is not provided with the G1029. Refer to
Figure 1
for recommended 220V receptacle.
Circuit Breaker:
The 2 HP motor will draw
roughly 13 amps @ 220V. We recommend using
a 20 amp circuit breaker. Circuit breakers rated
higher will not adequately protect the motor. If
you are using a fuse, we recommend 30 amp
slow blow 220V service. Fuses rated higher will
not adequately protect the motor.
CAUTION:
We have covered some basic electri-
cal requirements for the safe operation of your
Dust Collector. These requirements are not nec-
essarily comprehensive. You must be sure that
your particular electrical configuration complies
with local and state codes. Ensure compliance by
checking with your local municipality or a licensed
electrician.
Figure 1.
Recommended 220V receptacle.