Model G1023RL Series (Mfd. Since 12/11)
-11-
Serious injury could occur if you connect
the machine to power before completing the
setup process. DO NOT connect to power
until instructed later in this manual.
Circuit Requirements for
G1023RLWX
This machine is equipped with a power cord that
has an equipment-grounding wire and a grounding
plug. Only insert plug into a matching receptacle
(outlet) that is properly installed and grounded in
accordance with all local codes and ordinances.
DO NOT modify the provided plug!
Improper connection of the equipment-grounding
wire can result in a risk of electric shock. The
wire with green insulation (with or without yellow
stripes) is the equipment-grounding wire. If repair
or replacement of the power cord or plug is nec-
essary, do not connect the equipment-grounding
wire to a live (current carrying) terminal.
Check with a qualified electrician or service per-
sonnel if you do not understand these grounding
requirements, or if you are in doubt about whether
the tool is properly grounded. If you ever notice
that a cord or plug is damaged or worn, discon-
nect it from power, and immediately replace it with
a new one.
This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.
We do not recommend using an extension cord
with this machine. If you must use an extension
cord, only use it if absolutely necessary and only
on a temporary basis.
Extension cords cause voltage drop, which can
damage electrical components and shorten motor
life. Voltage drop increases as the extension cord
size gets longer and the gauge size gets smaller
(higher gauge numbers indicate smaller sizes).
Any extension cord used with this machine must
be in good condition and contain a ground wire
and matching plug/receptacle. Additionally, it must
meet the following size requirements:
Min. Gauge (G1023RL/RLW/RLX) .......14 AWG
Maximum Length (Shorter is Better).......50 ft.
Min. Gauge (G1023RLWX) ...................10 AWG
Maximum Length (Shorter is Better).......50 ft.
Grounding Requirements
Extension Cords
No adapter should be used with the plug. If
plug does not fit the available receptacle, or
if machine must be reconnected for use on
a different type of circuit, the reconnection
must be performed by an electrician or
qualified service personnel, and it must
comply with all local codes and ordinances.
Figure 2. Typical L6-30 plug and receptacle.
Grounding Prong
is Hooked
Current Carrying Prongs
L6-30 GROUNDED
LOCKING
RECEPTACLE
L6-30
LOCKING
PLUG
Nominal Voltage ......... 208V, 220V, 230V, 240V
Cycle ..........................................................60 Hz
Phase ............................................Single Phase
Circuit Rating ...................................... 30 Amps
Plug/Receptacle ...........................NEMA L6-30
This machine is prewired to operate on a power
supply circuit that has a verified ground and meets
the following requirements: