Model G0806/G0807 (Mfd. Since 12/15)
-15-
4. Use wire nuts to connect wires, as indicated
in
Figure 9. Twist all three wire nuts onto
their respective wires and wrap them with
electrical tape so they will not come loose.
The voltage conversion MUST be performed by
an electrician or qualified service personnel.
IMPORTANT: To perform the voltage conversion,
rewire the motor to the new voltage, rewire the
power transformer, correctly set the overload relay
dial, rewire the welding transformer, and install
the correct plug, according to the provided wiring
diagram.
Note: If the diagram included on the motor
conflicts with the one on
Pages 58– 59, the
motor may have changed since the manual was
printed. The diagram provided inside the motor
wiring junction box supersedes what is printed in
this manual.
Items Needed
Qty
•
Phillips Head Screwdriver #2 ..................... 1
•
Wire Cutters/Stripper .................................. 1
•
Electrical Tape ............................ As Needed
•
Wire Nut (12 AWG x 3) ............................... 1
•
NEMA 6-15 Plug ......................................... 1
•
Overload Relay (P0806422) ....................... 1
Voltage Conversion
(G0806)
MOTOR
220V
F
GND
Run
Capacitor
Run
Capacitor
45MFD
250VAC
Start
Capacitor
400MFD
125VAC
Figure 9. Model G0806 motor rewired to 220V.
To convert G0806 for 220V operation:
1. DISCONNECT MACHINE FROM POWER!
2. Remove 5-15 plug from power cord.
3. Remove motor junction box cover, then loos-
en wire nuts indicated in
Figure 8.
GND
Run
Capacitor
Run
Capacitor
45MFD
250VAC
Start
Capacitor
400MFD
125VAC
Figure 8. Location of wire nuts to be loosened
on Model G0806 when converting voltage.
Loosen
These
Wire Nuts
Connect
Wires with
Nuts Here
5. Open the electrical cabinet and remove the
wire attached to the 110V terminal on the
power transformer in the electrical panel (see
Figure 10). Connect it to the 220V terminal.
4
3
2
1
1
2
3
4
5
6
7
8
9
10
11
12
1
2
1
4
R
T
3
ELECTRICAL PANEL
E
GND
GND
1
2
6 6
1
U
W
1
2
TRANSFORMER
Ya Chang
Model: S-034-005-1
110V 1-Ph 50/60Hz
0V
110V
220V
2T1
6T3
4T2
2T1
6T3
4T2
1L1
5L3
13NO
3L2
97 NO
98 NO
95 NC
96 NC
A1
A2
A2
CU-18
240V
TECO Relay
RHU-10/1 7.2-10A
9
8
7.2
TRIP IND.
TEST RCA
21NC
22NC
14NO
R
O
13NO
21NC
14NO
10A
97NO
96NO
98NO
95NC
U
U
W
W
4
4
4
3
R
T
Contactor
TECO
2
1
T
2
2
T
T
T
R
R
R
0V
110V
R
2
1
Primary Voltage:
0V/110V/220V
Figure 10. Power transformer wire relocated
from 110V to 220V.
6. Remove the pre-installed overload relay and
replace it with the overload relay from the
voltage conversion kit (Part P0806422).
Wire
Reconnected
to 220V Terminal