Model G0568/G0569 (Mfd. Since 10/11)
-27-
Power Connection
Before connecting to power, read through the
SECTION 2: POWER SUPPLY section on Page
14 to check that your setup follows the safety and
circuit requirements for this machine. Be sure to
also have your electrician on hand for the "Test
Run" in case the power is connected out of phase
(Model G0569 only).
Attempting to connect this machine to the
power source without a qualified electrician
greatly increases the risk of electrocution,
fire, or machine damage.
To connect the bandsaw to the power
source:
1. Remove the screws securing the power sup-
ply terminal box.
Figure 31. G0569 terminal box connection.
L1
L2
Ground
Incoming
220V
1-Ph Power
To Magnetic
Switch
Ground
Incoming
220V/440V
3-Ph Power
To Magnetic
Switch
= For phase
converter wild
wire (if used)
3. Model G0569 3-Phase, 440V Operation
Only: Shut off the main power at the power
source circuit breaker and attach the wires to
the locking shut-off switch.
Model G0569 3-Phase, 220V Operation:
Connect the power cord with an L15-30 plug
to an L15-30 receptacle.
Note: When using a phase converter, con-
nect the manufactured power leg or "wild
wire" to the terminal indicated in
Figure 31.
This terminal can handle power fluctuation
because it is wired directly to the motor. The
other wires connect to the controls and must
be consistent to prevent damage.
2. Feed the power wires through the strain relief
on the bottom of the terminal box, tighten the
strain relief, connect the cord to the terminals
shown in
Figure 31 then re-install the termi-
nal box cover.
Summary of Contents for G0568