Model G0505 (Mfg. since 4/04)
-25-
Review the troubleshooting and procedures in this section to fix or adjust your machine if a problem devel-
ops. If you need replacement parts or you are unsure of your repair skills, then feel free to call our Technical
Support at (570) 546-9663.
SECTION 7: SERVICE
Troubleshooting
Motor & Electrical
Symptom
Possible Cause
Possible Solution
Machine does not
start or a breaker
trips.
1. Switch disabling key removed.
2. Power supply switched
OFF or at fault.
3. Plug/receptacle at fault/wired wrong.
4. Wall circuit breaker tripped.
5. Wiring open/has high resistance.
6. Motor brushes at fault.
7. Motor ON/OFF switch at fault.
8. Motor at fault.
1. Install switch disabling key.
2. Ensure power supply is on/has correct voltage.
3. Test for good contacts; correct the wiring.
4. Ensure circuit size is correct/replace weak breaker.
5. Check/fix broken, disconnected, or corroded wires.
6. Remove/replace brushes (
Page 23).
7. Replace switch.
8. Test/repair/replace.
Machine stalls or is
underpowered.
1. Workpiece material not suitable for
machine.
2. Belt slipping.
3. Plug/receptacle at fault.
4. Motor brushes at fault.
5. Pulley slipping on shaft.
6. Motor bearings at fault.
7. Motor overheated.
8. Motor at fault.
1. Only plane natural wood; ensure moisture is below
20%.
2. Replace belt (
Page 28).
3. Test for good contacts/correct wiring.
4. Remove/replace brushes (
Page 23).
5. Replace loose pulley/shaft.
6. Test/repair/replace.
7. Clean motor, let cool, and reduce workload.
8. Test/repair/replace.
Machine
has
vibration or noisy
operation.
1. Motor or component loose.
2. Knives at fault.
3. Belt worn or damaged.
4. Pulley loose.
5. Incorrectly mounted to workbench.
6. Motor mount loose/broken.
7. Motor bearings at fault.
8. Chip deflector or dust hood loose or
damaged.
1. Inspect/replace damaged bolts/nuts, and re-tighten
with thread locking fluid.
2. Resharpen/replace knives; set knife alignment/
height correctly.
3. Inspect/replace belt.
4. Realign/replace shaft, pulley, setscrew, and key.
5. Adjust feet, shim, or tighten mounting hardware.
6. Tighten/replace.
7. Test by rotating shaft; rotational grinding/loose shaft
requires bearing replacement.
8. Properly re-install/replace.
Summary of Contents for G0505