3.2 Connection UNITS-TRANSFORMER BOX
NOTE:
The polarity and the colour of the connection cables must be strictly respected
It is possible to connect from a minimum of 1 to a maximum of 6 PARADE D18 units to the
Separate Transformer Box.
If only PARADE D9 units are used, it is possible, as shown in picture 5, to connect up to 12
projectors.If only PARADE D27 are used, it is possible to connect up to 4 projectors to the
Separate Transformer Box.
The maximum number of light sources that can be connected to the Separate Transformer Box
cannot exceed 108.
11
2
BROWN
BLUE
+12V DC
GND
BLACK
Signal -
RED
3
Cable 2x1.5 mm
2
+ 2x0.34
mm
2
minimum section
PARADE
Junction boxes for the
connection of the units
Start wiring
from junction
box N°1