4.2 DMX Channels
5.0 MAINTENANCE
To ensure maximum performance and light output, it is recommended to follow these instructions:
- carefully check the electrical connections, particularly the ground connection;
- replace all damaged components.
6.0 TECHNICAL INFORMATION
TRANSFORMER BOX
Size
L238 x P250 x H100
mm
Weight
3,5
Kg
Body
Aluminium
Operating Voltage
100-240
V
Operating Frequency
50/60
Hz
Operating Amperage
0.9A@230V
A
Power absorbed
206W
W
Protection rating
IP65
15
This equipment can be installed on normally
inflammable surface