Default brewing interface passcode is 1234.
Default service menu passcode is 4003.
USB programing is one of the ways a user can change
the default recipes. After the recipes are updated using
the touch screen user interface, the programs can be
uploaded to a USB (Universal Serial Bus) drive by means
of the USB port on the front top of the brewer above
the center of the screen. The uploaded USB drive then
can be used to transfer the recipes and setting to other
machines reducing the setup time of future unit. The
USB transfer ability allows for standardized programs
between locations and simplifies service technician’s
work.
The USB drive must have a type-A connection, have USB
2.0 capability, and a minimal 2 GB of storage space.
SOFTWARE INFORMATION TRANSFER:
To upload or download settings, recipes, or images:
Select USB icon in the LCD display.
Default passcode & passcode setup: Select Passcode icon
under Settings on LCD display.
Programming
Backlighting Lighting Color sequences:
If freshness timer setting is “ON”:
•
Solid Green backlighting: After brewing;
30-5 minutes remaining in the freshness
timer
•
Solid Yellow backlighting: 5 to 0 minutes
remaining in the freshness timer
•
Solid Red backlighting: Freshness timer
elapsed
If freshness timer setting is “OFF”:
Backlighting randomly cycles colors as long a
the shuttle is on the brewer
Error states:
Flashing Blue: Fan not spinning
Flashing Red: Air heater over-temp
Flashing Green: Air temperature thermistor out of
range
Air-Heated Shuttle Lighting