8
Cecilware
®
Coffee Urns
Thermostat Adjustment (continued)
3. Allow a few minutes for the temperature to reach
set level. The Heater Light will go ON, indicating the
heating element is activated, wait for it to go OFF,
indicating that the water has reached new set
temperature.
4. Take a temperature reading and repeat if necessary.
Digital Display Temperature Adjustment
1. Press up and down arrows until desired
temperature is displayed.
Solid-State Timer Adjustment (FE models)
A factory pre-set electronic solid-state timer controls the
volume of water for each brew cycle. If more or less
water is desired, follow these instructions:
1. Turn knob of timer clockwise to increase volume of
water or counterclockwise to decrease it.
2. Run through a complete brew cycle after each
adjustment. Since timer cannot be readjusted in
mid-cycle, simply push cycle stop switch at bottom
right of side box if water gets too high.
3. If maximum setting of timer fails to deliver enough
water, check water pump and spray head and
follow instructions under
Maintenance
.
Mechanical Timer Adjustment (CL models)
The factory pre-set mechanical timer can be adjusted
for more or less water by following these instructions:
1. Remove timer knob and loosen lock nut holding
stop pin.
2. To increase volume of water, rotate stop pin
clockwise.
3. To decrease, rotate counterclockwise. Tighten lock
nut and replace knob.
Spray Arm By-Pass Adjustment (All Urns )
Adjustable bypass allows proper brew extraction even
with variations caused by soft or treated water. If bypass
requires adjustment to correct for local water
conditions, proceed as follows:
1. Position spray head over center of coffee liner and
press BREW switch.
2. Turn by-pass adjustment screw clockwise to
decrease by-pass flow (for stronger coffee) or
counter-clockwise to increase by-pass flow (for
weaker coffee).
3. At end of brewing cycle, note volume of water in
coffee liner. Readjust timer if necessary to obtain
the correct volume of water.
WARNING: SHOCK HAZARD
Disconnect power before attempting any electrical
repairs.
Thermostat Bulb
Coupling
Nut
CCW - Decrease
Temperature
WARNING: SHOCK AND BURN HAZARD
To prevent electric shock and burn hazard, all tasks
described in this section are to be performed by a
trained and qualified service technician.
Adjustments (continued)
Single Timer
(120V - L205A)
(240V - L210A)
Dual Timer
(120V - L214A)
(240V - L216A)
Manual Timer
(L154A)
Thermostat Assy
(L029A)