![Grindmaster Cecilware CL100N Series Operator'S Manual Download Page 7](http://html1.mh-extra.com/html/grindmaster-cecilware/cl100n-series/cl100n-series_operators-manual_2265600007.webp)
Coffee Urns
Cecilware
®
7
NOTICE:
All sanitizing agents in the food zone must
comply with 21 CFR 178.1010. Sanitize all food
dispensing units periodically. All parts to be sanitized
must be cleaned first. Cleaning and sanitizing frequency
must follow state and local health department
regulations.
NOTICE:
Do not use cleansers, bleach liquids,
powders, or any other substance containing chlorine.
These products promote corrosion and will pit the
stainless steel. USE OF THESE PRODUCTS WILL VOID THE
WARRANTY.
After Each Brew:
1. Dispose of grounds and rinse brew basket.
Every Day:
1. Drain the urn; then run a brew cycle of hot water.
After spraying hot water into the liner, thoroughly
brush the liner with a long handled brush.
2. Drain the water and repeat step one. Run another
brew cycle. Brush the liner and drain.
3. Wash the wire brew baskets with urn cleaner and
rinse thoroughly.
Weekly or Bi-Weekly, Depending on Use:
1. Fill the urn liners with several gallons of hot water.
2. Pour into the liner the recommended concentration
of urn cleaning compound. Set the thermostat to
high (NO. 10) and then run a brew cycle of hot
water.
3. Allow solution to remain in the liner for
approximately 30 minutes.
4. Scrub the inside of both the liner and the cover with
a long handled brush.
5. Drain the cleaning solution from the liner. Rinse by
running several brew cycles with the sprayhead
centered over the liner. Be sure to drain the rinse
water between cycles.
6. Thoroughly clean the faucets.
7. Use a long, thin gauge glass brush to clean the
coffee gauge glass. Use the same brush to clean the
fitting at the bottom of the liner and the pipe
connected to the coffee faucet.
8. Reassemble faucets. Fill the liners with hot water
and drain until the liner and all parts are completely
rinsed.
Adjustments
Thermostat Adjustment
The Thermostat is factory set for proper dispense
temperature of 200°F ± 3°F with the control knob set to
the maximum clockwise position. If field adjustments
are needed proceed as follows:
• To DECREASE temperature, turn the control knob
slightly in the COUNTERCLOCKWISE direction.
• To INCREASE the water temperature -
1. With the Thermostat Knob to its maximum
clockwise position, remove the knob and locate the
slotted adjustment screw inside the hollow
thermostat shaft.
2. Using a narrow-bladed screwdriver, engage slotted
adjustment screw and turn it 1/4 turn slowly
counter-clockwise.
(continued next page)
WARNING: SHOCK AND BURN HAZARD
To prevent electric shock and burn hazard, all tasks
described in this section are to be performed by a
trained and qualified service technician.
Thermostat Adjustment
CAUTION: BURN HAZARD
The urn surfaces and water inside jacket are very hot.
Use caution when cleaning this urn to prevent burns.
CAUTION: BURN HAZARD
Never remove the faucet when the liner has water or
coffee in it. Switch OFF the power to the unit at the
circuit breaker. Turn off the water line running to the
urn.
Faucet Body
Seat Cup
X014A
Bonnet
Faucet Handle
Faucet Assembly (D017A)
Cleaning