6. Repeat
Priming
instructions on page 6.
NOTE: DO
NOT TURN ON THERMOSTAT UNTIL URN IS
PRIMED.
If Water from Cold Water Supply Line Does Not
Enter Urn
1. Check water supply to external shut-off valve.
2. Check fuse on rear of side box and replace if
necessary.
3. If water supply and fuse are okay, remove fuse and
lift off side box door exposing terminal block and
electrical wiring.
4. Check dual probe liquid level controller. (See
Component Tests
)
If Water Runs Out At Overflow Drain
1. Make sure urn is level and overflow tube is vertical.
2. Remove fuse from rear of side box.
3. If water continues to flow, solenoid valve is dirty or
not seating properly. Replace solenoid as described
below.
Replacing Solenoid
1. Shut off water supply, remove fuse, and lift off side
box door.
2. Disconnect wires from solenoid: then remove flare
nut and unscrew solenoid valve from bracket.
3. Install new solenoid and reinstall fuse and side box
door.
4. If necessary, follow
Priming
instructions on page 6.
No Water from Spray Head
1. Check fuse first.
2a For FE urns: Depress BREW switch and release. If
switch remains lit, water pump is probably not
operating. Lift off side box door and check if fan on
water pump is rotating. If not, replace pump as
described below.
2b. For CL urns: Turn brew timer knob clockwise.
Replace timer if it does not go on. If timer goes on
but pump doesn't, replace pump.
Replacing Water Pump
1. Shut off water supply and remove fuse. Drain urn
to level of water faucet.
2. Lift off side box door and disconnect the two pump
wires.
3. Loosen union fittings on pump and remove pump
from urn.
NOTICE: If your urn has older style
pump with copper connections, it is imperative
that you use a counter wrench when removing
and installing pump to avoid damaging copper
tubing. DO NOT OVERTIGHTEN.
4. Replace pump and follow
Priming
instructions on
page 6.
Checking Solid-State Timer (FE Urns)
1. Press and hold BREW switch for 10 seconds. Brew
cycle should start. If water stops coming from spray
head as soon as BREW switch is released, timer is
not operating. Replace it. (Instructions below.)
2. If no water comes from spray head when BREW
switch is pressed, replace switch.
NOTE: To check mechanical timer on CL urns, refer to
No Water from Spray Head
.
Replacing Solid-State Timer
1. Remove fuse, lift off side box door, and remove
timer from bracket.
2. Carefully note locations of colored wires on timer
board and then remove wires.
3. Replace timer and reassemble unit in reverse order.
Blending - Automatic Type (FE Urns)
Operation:
The agitator pump circuit is programmed to operate
immediately after brewing cycle. The circuit pumps air
through the coffee gauge glass(es) into the coffee
liner(s). The complete cycle takes about 20 seconds. For
additional blending, simply press the BLEND switch.
Maintenance:
• If agitation is not sufficient to blend coffee, check
flexible tubing, and glasses and fittings, for possible air
leaks. Replace as necessary.
• If agitator pump does not operate immediately after
brewing cycle or when BLEND switch is pressed, replace
agitator pump or solid state agitator timer.
• If agitator pump comes on immediately after brewing
cycle, but does not operate when BLEND switch is
pressed, replace BLEND switch.
Blending - Manual Type (CL Urns)
Operation:
Immediately after brewing cycle, depress BLEND switch
and hold for about 20 seconds. Your coffee will be
completely blended and ready to serve.
Maintenance:
• If agitator pump does not operate when BLEND
switch is pressed, replace switch, if pump still does not
operate, replace pump.
Tank Control Board Error Codes
ERROR1 – fill timeout
ERROR2 – temperature probe error
ERROR4 – no change in temperature when expected
10
Cecilware
®
Coffee Urns
WARNING: SHOCK AND BURN HAZARD
To prevent electric shock and burn hazard, all tasks
described in this section are to be performed by a
trained and qualified service technician.
WARNING: SHOCK HAZARD
Disconnect power before attempting any electrical
repairs.