Grindmaster Cecilware CL100N Series Operator'S Manual Download Page 1

Operator Manual

Grindmaster-Cecilware

4003 Collins Lane, Louisville, KY 40245 USA 
Phone: 502.425.4776 Toll Free: 800.695.4500
Fax: 502.425.4664
Web: gmcw.com  Email: [email protected]

Safety Information..................2
Rough-In Drawings .................3
Electrical Specifications...........5
Installation...............................5
Priming ....................................6
Operation ................................6

Cleaning...................................7
Adjustments ............................7
Maintenance ...........................8
Parts Diagram........................12
Parts List.................................14
Wiring Diagram.....................16

Thank you for purchasing this quality urn. For your safety and the safety of others, read all warnings and the
operator manual before installing or using the product. Properly instruct all operators. Keep training records. For
future reference, record serial number here:

Table of Contents

©2018 Grindmaster-Cecilware

Printed in USA

0518 Form # CW-326-02

Part # 390-00070

Grindmaster-Cecilware provides the
industry’s BEST warranty. Visit gmcw.com
for warranty terms and conditions.

Model FE300

Model FE100N

Coffee Urns

FE75N, FE100N, FE200, FE300,

CL75N, CL100N, CL200 Series

Activate your warranty now at

http://gmcw.com/warranty-registration

Summary of Contents for CL100N Series

Page 1: ...is quality urn For your safety and the safety of others read all warnings and the operator manual before installing or using the product Properly instruct all operators Keep training records For future reference record serial number here Table of Contents 2018 Grindmaster Cecilware Printed in USA 0518 Form CW 326 02 Part 390 00070 Grindmaster Cecilware provides the industry s BEST warranty Visit g...

Page 2: ...eforming the plug may cause electrical shock damage unit and will void warranty To reduce risk of explosion or fire do not use near combustibles WARNING Safety Information 2 Cecilware Coffee Urns Important Safety Information This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death...

Page 3: ... Electro Mechanical Timer 19 3 4 0 29 1 3 5 2 5 O F F 9 8 7 6 5 4 3 2 1 10 NN10A 14 0 16 0 5 4 10 1 29 1 4 0 19 3 28 0 O FF 9 8 7 6 5 4 3 2 1 10 NN10A 5 4 3 5 2 5 14 0 10 1 FE100N Twin 3 Gallon Urn Adjustable By pass Automatic Agitator and Solid State Timer CL100N Twin 3 Gallon Urn Adjustable By pass Push Button Agitator and Electro Mechanical Timer TEMPERATURE CONTROL 195 TEMPERATURE CONTROL 195 ...

Page 4: ...e Timer CL200 Single 6 Gallon Urn Adjustable By pass Push Button Agitator and Electro Mechanical Timer FE300 Twin 10 Gallon Urn Adjustable By pass Automatic Agitator and Solid State Timer 31 2 4 0 16 0 32 0 5 4 21 2 2 5 O FF 9 8 7 6 5 4 3 2 1 10 NN10A 3 5 10 1 34 5 4 0 18 0 36 1 5 4 23 4 2 5 O FF 9 8 7 6 5 4 3 2 1 10 NN10A 3 5 9 1 ...

Page 5: ...nto a drip trough or drain receptacle of some type 5 Level urn by adjusting legs Then attach faucets and install vent cap drain 6 Cover s are shipped with knob s on inside to prevent damage Simply unscrew and reverse WARNING ELECTRIC SHOCK HAZARD Installation of this appliance should be performed by qualified service personnel only Improper installation could result in electrocution CAUTION These ...

Page 6: ...center gauge glass left hand gauge glass on 3 gallon single urns Then turn thermostat knob to 10 thermostat pilot light shows heater is on Urn jacket will continue to fill automatically until water reaches the proper level 4 When indicator on dial thermometer approaches the W in BREW zone 195 F 92 C urn is ready to brew coffee 5 In high altitude locations over 5000 ft above sea level thermostat ma...

Page 7: ...ure to drain the rinse water between cycles 6 Thoroughly clean the faucets 7 Use a long thin gauge glass brush to clean the coffee gauge glass Use the same brush to clean the fitting at the bottom of the liner and the pipe connected to the coffee faucet 8 Reassemble faucets Fill the liners with hot water and drain until the liner and all parts are completely rinsed Adjustments Thermostat Adjustmen...

Page 8: ...et mechanical timer can be adjusted for more or less water by following these instructions 1 Remove timer knob and loosen lock nut holding stop pin 2 To increase volume of water rotate stop pin clockwise 3 To decrease rotate counterclockwise Tighten lock nut and replace knob Spray Arm By Pass Adjustment All Urns Adjustable bypass allows proper brew extraction even with variations caused by soft or...

Page 9: ...on If thermostat pilot light does not come on replace thermostat Refer to instructions below If pilot light is on measure continuity between terminals l and 2 of thermostat and between terminals 3 and 4 If a resistance is measured replace thermostat 3 If thermostat is okay check wiring and repair if necessary if wiring is okay check heater resistance if high or infinite replace as follows Replacin...

Page 10: ... 1 Press and hold BREW switch for 10 seconds Brew cycle should start If water stops coming from spray head as soon as BREW switch is released timer is not operating Replace it Instructions below 2 If no water comes from spray head when BREW switch is pressed replace switch NOTE To check mechanical timer on CL urns refer to No Water from Spray Head Replacing Solid State Timer 1 Remove fuse lift off...

Page 11: ...r the wire is disconnected from the Probe the problem may be in the Solid State Dual Level Control Board 3 If water starts flowing into the tank the Probe may be grounded due to excessive liming Check with Ohm meter 4 Clean or replace probe Dual Probe Liquid Level Controller Test Check the Controller as follows 1 Make sure there is power input to the Controller at the terminals AC1 AC2 Your voltme...

Page 12: ...12 Cecilware Coffee Urns AUTOMATIC COFFEE URNS 17 34 9 FE CL Parts Diagram refer to key on page 15 ...

Page 13: ...lly in hard water areas remove and clean spray head cap and spray head disc frequently To clean swivel valve loosen nut and remove spray arm assembly from urn Remove sediment by inserting a pipe cleaner through small hole in valve If maximum setting of timer fails to deliver enough water check water pump Parts Diagram continued refer to key on page 15 ...

Page 14: ... WATER INLET VALVE 120V ONLY 35 GPM 1 1 1 1 1 1 CD418 WATER INLET VALVE 240V 35 GPM 1 1 1 1 1 1 280 00020 WATER INLET VALVE 50 GPM 120V ONLY 1 1 280 00020 C223AL WATER INLET VALVE 50 GPM 240V COIL 1 1 7 CH243 WIRING HARNESS 1 1 CH244 WIRING HARNESS 1 CH387 WIRING HARNESS MECH TIMER 1 1 343 00128 WIRING HARNESS 120V ONLY 1 1 1 1 343 00129 WIRING HARNESS 240V 1 1 1 1 8 355 00032 SIGHT GLASS ASSEMBLY...

Page 15: ...OCK 2 2 2 3 3 3 3 3 3 22 344 00038 LEVEL SENSOR DUAL PROBE 1 1 1 1 1 1 1 1 1 23 L007A THERMOMETER BREW DIAL 1 1 1 1 1 1 1 1 1 24 L154A TIMER MECHANICAL 0 15 MINUTES 1 1 1 25 L205A TIMER SINGLE 120V 1 1 1 L210A TIMER SINGLE 240V 1 1 1 L214A TIMER DUAL 120V 1 1 1 L216A TIMER DUAL 240V 1 1 1 26 L155AL ROCKER SWITCH POWER ON OFF 1 1 1 1 1 1 L019A SWITCH POWER ON OFF 1 1 1 27 L238A DELAY TIMER SOLID ST...

Page 16: ... TIMER GND GND Blue Yel Yel Yel Yel Red Red Wht Wht Yel Gray BREW SWITCH FE N D SERIES W SINGLE TIMER NC NO C NC NO C NC NO C C NC NO SWITCH CONFIGURATION 520 75 16 250 5 72 5 3803 7 7 0 5 8 5 72 7 0 5 5 72 5 3803 THERMISTOR P1 P5 P3 P2 TRANSFORMER RELAY FILL L L L N N YEL WATER LEVEL PROBES WATER GND TANK CONTROL BOARD RED WATER INLET VALVE ...

Page 17: ...GITATOR PUMP CONTACTOR POWER SWITCH FUSE L2 L1 N FOR 120V SINGLE TIMER GND GND Blue Blue Yel Yel Yel Yel Red Red WHT Wht Yel Gray BREW SWITCH FE N SERIES W SINGLE TIMER NC NO C NC NO C NC NO C C NC NO SWITCH CONFIGURATION THERMISTOR P1 P5 P3 P2 TRANSFORMER RELAY FILL L L L N N YEL WATER LEVEL PROBES WATER GND TANK CONTROL BOARD ...

Page 18: ...P5 P3 P2 TRANSFORMER RELAY FILL L L L N N YEL WATER LEVEL PROBES WATER GND TANK CONTROL BOARD RED WATER INLET VALVE DELAY TIMER BLEND BREW PUMP HALF BREW LIGHT STOP BREW SWITCH DUAL TIMER Blue Yel Yel Yel Yel Red Red Wht Yel Wht HALF BREW SWITCH BREW LIGHT Purple Purple Wht Wht NC NO C NC NO C NC NO C NC NO C C NC NO SWITCH CONFIGURATION WHT Yel Gray ...

Page 19: ... Yel Yel Yel Red Red Wht Yel Gray Wht HALF BREW SWITCH BREW LIGHT Purple Purple Wht Wht FE N SERIES W DUAL TIMER GND GND NC NO C NC NO C NC NO C NC NO C C NC NO SWITCH CONFIGURATION RED WATER INLET VALVE CONTACTOR POWER SWITCH FUSE L2 L1 N FOR 120V WHT THERMISTOR P1 P5 P3 P2 TRANSFORMER RELAY FILL L L L N N WATER LEVEL PROBES WATER GND TANK CONTROL BOARD YEL ...

Page 20: ... continued C NC NO SWITCH CONFIGURATION NC NO C RED WATER INLET VALVE CONTACTOR POWER SWITCH FUSE L2 L1 N FOR 120V WHT THERMISTOR P1 P5 P3 P2 TRANSFORMER RELAY FILL L L L N N YEL WATER LEVEL PROBES WATER GND TANK CONTROL BOARD CL N D SERIES ...

Page 21: ...m continued CL N SERIES C NC NO SWITCH CONFIGURATION NC NO C RED WATER INLET VALVE CONTACTOR POWER SWITCH FUSE L2 L1 N FOR 120V WHT THERMISTOR P1 P5 P3 P2 TRANSFORMER RELAY FILL L L L N N YEL WATER LEVEL PROBES WATER GND TANK CONTROL BOARD ...

Page 22: ...gram continued C NC NO SWITCH CONFIGURATION RED WATER INLET VALVE CONTACTOR POWER SWITCH FUSE L2 L1 N FOR 120V WHT THERMISTOR P1 P5 P3 P2 TRANSFORMER RELAY FILL L L L N N YEL WATER LEVEL PROBES WATER GND TANK CONTROL BOARD CH N D SERIES ...

Page 23: ...YEL WATER LEVEL CONTROL WATER LEVEL PROBES GND 6 COMMON 4 L LEVEL 5 H LEVEL 3 AC 2N 1 FILL 2 AC 1L WATER LED L1 L2 DELAY TIMER BLEND BREW PUMP BREW LIGHT STOP WATER INLET VALVE AIR AGITATOR PUMP CONTACTOR THERMOSTAT POWER SWITCH FUSE L2 L1 SINGLE TIMER GND GND Blue Blue Yel Yel Yel Yel Red Red Wht Wht Yel Gray BREW SWITCH NC NO C NC NO C NC NO C C NC NO SWITCH CONFIGURATION H4 GND JUMP 385 25 51 7...

Page 24: ...24 Cecilware Coffee Urns Wiring Diagram continued 25 8720 7 2 8516 7 50 1 2 7 50267 7 3 27 7 5 7 56 3 27 7 50 1 2 7 50267 7 1 1 1 7 7 7 2 7 50 1 2 7 50267 7 3 27 217 725 7 56 3 3 3 3 ...

Page 25: ...ilware 25 Wiring Diagram continued 1 5 3803 5 12 9 21752 9 9 7 5 3803 3 5 6 7 50 1 2 5 5 5 8 6723 2 1 1 7 0 5 86 5 6 7 5 251 51 7 7 21 6 7 17 59 7 0 5 51 251 5 3 27 7 50267 7 7 7 7 217 725 2 3 6 7 56 5 5 5 8 8 5 5 5 5 ...

Page 26: ... 1 5 3803 5 12 9 21752 9 9 7 5 3803 3 5 6 7 50 1 2 5 5 5 8 6723 2 1 1 7 0 5 86 5 6 7 7 5 251 51 51 51 7 7 7 21 6 7 17 59 7 0 5 51 251 5 26 Cecilware Coffee Urns Wiring Diagram continued ...

Page 27: ...ns Cecilware 27 Wiring Diagram continued 1 5 3803 5 2 5 217 76 9 21752 7 5 62 7 5 3803 3 5 6 1 7 50 1 2 7 7 8 8 5 5 7 6723 2 1 1 2 1 1 62 67 7 7 0 5 86 7 8 7 7 7 7 251 251 8 8 51 51 51 7 7 7 21 6 7 17 59 7 0 5 7 ...

Page 28: ...28 Cecilware Coffee Urns ...

Page 29: ...Coffee Urns Cecilware 29 ...

Page 30: ...ilware 4003 Collins Lane Louisville KY 40245 USA Phone 502 425 4776 Toll Free 800 695 4500 Fax 502 425 4664 Web gmcw com Email info gmcw com 2018 Grindmaster Cecilware Printed in USA 0518 Form CW 326 02 Part 390 00070 ...

Reviews: