7.3 The pump does not start, for pumps with SMART
™
Cause
Remedy
The phase sequence may
be incorrect.
1. Pull out the plug.
2. Do one of the following:
– Shift two phases by turning two contact pins
with a screwdriver.
NOTICE:
Do not take the plug apart.
WS002614A
Figure 4: CEE plug
– Turn the knob to the opposite position 1, with
8 seconds delay.
NOTICE:
Do not reverse the phase sequence while the
motor is running. Doing so may cause
incorrect rotation resulting in damages to the
motor electronics and the rotating parts.
Respect the 8 seconds delay.
WS002616A
WS002615A
Figure 5: Phase shifter On/Off switch
– If no glove or phase shifter is used, then shift
two phase conductors in the cabinet.
If the problem persists, then contact a sales or authorized service
representative.
Always state the product number and the serial number of the pump, see
on page 10.