6.4 Change the oil
A paraffin oil with viscosity close to ISO VG32 is recommended. The pump is
delivered from the factory with this type of oil. Examples of suitable oil types are
the following:
• Statoil MedicWay 32
™
• BP Enerpar M 004
™
• Shell Ondina 927
™
• Shell Ondina X430
™
In applications where poisonous properties are of less concern, a mineral oil with
viscosity up to ISO VG32 can be used.
Empty the oil
1. Lay the pump on its side.
Lock the pump with supports to prevent it from rolling over.
2. Remove the oil screw.
CAUTION: Compressed Gas Hazard
Air inside the chamber may cause parts or liquid to be propelled
with force. Be careful when opening. Allow the chamber to de-
pressurize before removal of the plug.
3. Turn the pump so that the oil hole faces downwards and let the oil run out
into a container.
Fill with oil
1. Replace the oil screw O-ring.
2. Put one of the oil screws back and tighten it.
3. Turn the pump so that the oil hole faces upwards and fill with new oil.
Pump
Oil Quantity, L (qt)
8120.280
0.45 (0.48)
4. Put the oil screw back and tighten it.
6.5 Replace the impeller
6.5.1 Remove the impeller
CAUTION: Cutting Hazard
Worn parts can have sharp edges. Wear protective clothing.