![Grindex 8120.280 Sandy Inox Installation, Operation And Maintenance Manual Download Page 23](http://html.mh-extra.com/html/grindex/8120-280-sandy-inox/8120-280-sandy-inox_installation-operation-and-maintenance-manual_2265326023.webp)
WS003575D
COLOUR STANDARD
BN=Brown
BK=Black
WH=White
OG=Orange
GN=Green
GNYE=Green-Yellow
RD=Red
GY=Grey
BU=Blue
YE=Yellow
PHASE SHIFTER ON MOTOR CABLE
*SUBCAB AWG
**GC= Ground check
L3 GY/WH*
L2
L3 GY/WH*
L2 BK/BK*
L1 BN/RD*
V
W
U
L3
L1
L2 BK/BK*
L1 BN/RD*
GNYE
GNYE
Motor cable from grid
(4/4* conductors)
Motor cable to pump
(4/4* conductors)
1 - 0 - 1
min 20m
51 622 00 /7
766 71
01
Pump
8115
8116
8117
8118
8119
8120
H
L3
A2 13 14
SMART
L1
L2
L3
2 4 6
1 3 5
A2
K1M
A1
BN
INTERNAL DIRECT ON LINE
BK
GY
F
L1
G
L2
BN/RD*
GY/WH*
BK/BK*
15 16
L3 GY/WH*
Motor cable
(6/7*
conductors)
T1 WH/BU*
T2 WH/OG*
YE*
GNYE/*
GC**
L1 BN/RD*
L2 BK/BK*
EXTERNAL STARTER, DOL
B
Terminal
plate
C
A
E
D
Pump
EXTERNAL STARTER, Y/D
L1 1BK
L3 3BK
L2 2BK
Motor cable
(7 conductors)
L3 6BK
L2 5BK
T1 WH
L1 4BK
T2 WH
GNYE
V1
Terminal
plate
U1
W1
V2
13
14
U2
W2
Pump
B
Terminal
plate
C
A
E
D
Pump
Var. 00/01
Var. 02
A
B
C
D
E
U1
V1
W1
13
U2
V2
W2
14
INTERNAL STAR /DELTA
L3
L2
L1
BN/RD*
BK/BK*
GY/WH*
3 sek.
SMART
F G H
A2 16 15
A1
T
NC
16
A1
A2
A1
A2
1 3
K1M
NC
BN
BN
BK
GY
BK
GY
BN
BK
GY
5 21
2 4 6 22
1 3
K2M
NC
5 21
2 4 6 22
18 A2
NO
15
14 13
Pump
V1
Terminal
plate
U1
W1
V2
W2
U2
14
13
4.5 Check the phase sequence: Pumps with built-in motor
protection
Follow this procedure if your product is equipped with the rotation control
SMART
™
.
4 Installation
8120.280 Sandy Inox Installation, Operation, and Maintenance Manual
21
Summary of Contents for 8120.280 Sandy Inox
Page 1: ...www grindex com Installation Operation and Maintenance Manual 8120 280 Sandy Inox ...
Page 2: ......
Page 41: ......
Page 42: ......
Page 43: ......