COMPONENT MAINTENANCE MANUAL
IN 1502H RADAR INDICATOR
TM109102
4-2
May/01
3. Equipment Setup
CAUTION
The IN-1502H contains high voltages that represent a poten-
tial electrocution hazard to service personnel. Always follow
safe and accepted high-voltage service practices when oper-
ating this equipment with the dust cover removed. The CRT
in the IN-1502H can store a dangerous charge for long peri-
ods of time even after the power has been removed from the
IN-1502H unit.
Table 4-2 Equipment Setup
TEST PANEL 8050362
POWER
OFF
UUT
OFF
RED
DOWN
BLUE
DOWN
GRN
DOWN
COLOR BAR
DOWN
INTLC
DOWN
YOKE PLRT
DOWN
CROSSHATCH CRS
DOWN
CROSSHATCH FINE
DOWN
5 VDC/28 VDC
28 VDC
FLIR ENABLE
DOWN
IND DISABLE
DOWN
RS170/PAL
PAL
DIGITAL MULTIMETER
POWER
ON
MODE
DCV
RANGE
200