MAINTENANCE 

The 

eDrive  +2.0 

is equipped with smart logic to indicate when your commercial door will require servicing. When the STATUS 

indicator flashes constantly please contact your commercial door dealer to arrange a routine door service. 

Frequently examine the installation for imbalance and signs of wear or damage to cables, springs and mounting. Do not use if 
repair or adjustment is necessary. Power must be turned off before servicing, cleaning or adjusting the opener. 

 

* Service Status Indicator is factory set to OFF. To enable this feature a Chamberlain Hand Held Diagnostic tool is required.  Ser-
vice interval must be determined by the installer based on the projected door usage. 

 

Certain mechanical aspects of the installation must be checked, see below: 

 

Monthly 

− Examine the installation for imbalance and signs of wear or damage to cables, springs and mounting. Do not use if repair or  

   adjustment is necessary * 

− Check chain alignment, tension and condition. Adjust / replace if required * 
− Check PE / IR beam/s and bump edge functionality where applicable 

 

Quarterly 

− Check tightness of fixing bolts and (sprocket) grub screws. Adjust if required * refer page 7 
− Check correct electrical operation 
− Check manual operation via hand chain 
− Lubricate the drive chain * 
− Check door balance. The drive chain should display a transition of tension from one side of the linkage to the other in the lo

wer 

  half of the roller door travel. This transition is the ‘balance’ point. Adjust if required * 

− Conduct door maintenance in accordance with door manufactures guidelines. This will include door balance * 

 

* SERVICE MUST BE CARRIED OUT BY A QUALIFIED TECHNICIAN 

 

To view total cycles (limits must be set) 

 

 

Drive to door to closed limit.

 

 

Press and hold CLOSE for 10 seconds.

 

 

After 10 seconds and while still holding CLOSE, press and release the SET button.

 

 

Status LED will light up indicating number of cycles performed.

 

 

To read number of cycles, follow the ‘Reading Status Flashes’ routine described below. 

 
Reading Status Flashes 
 

 

STATUS indicator will start flashing to signify the value of the least significant digit of the overall number. A solidly lit indi-
cator stands for zero.

 

 

Press set to view the next digit.

 

 

Continue previous step until the STATUS indicator flashes quickly for 1 second then goes out. This signifies that the entire 
number has been displayed.

 

 

To reset error  

(This process indicates there has been a severe problem. Persistent resetting will void warranty and may damage the door and/or 
opener). This procedure will only work when the status light is flashing 

4

5

9

10

14 

or 

15

 times. 

 

Hold the STOP button for 10 seconds 

 

While still holding the STOP button, press and release the SET button

 

The STATUS indicator should flash quickly for 1 second. Any errors that were flashing should have stopped. 

 

HHDT (Handheld Diagnostic Tool) 

The  HHDT  allows  you  to  set  service  interval  warnings,  and  view  numerous  statistics  and  information 
including,  total  cycles,  cycles  since  service,  viewing  software  version,  number  of  transmitters  pro-
grammed and load reversals. 
The input can be found in the corner of the MCB adjacent to the ACEM terminal, see page 17  No.15. 
 
The diagnostic tool is also used to enable the service cycle alert (refer HHDT manual for procedure). The 
2.0 service cycle alert is factory set in disabled mode. 

Power MUST be turned off before servicing or adjusting the opener. Disconnect the supply when cleaning! 

Summary of Contents for eDrive +2.0

Page 1: ...opener www grifco com au www grifco co nz D M RDO 006 413062 Chamberlain Australia Pty Ltd PO Box 1446 Lane Cove NSW 1595 Australia Phone toll free 1800 474 326 Chamberlain New Zealand Ltd PO Box 100...

Page 2: ...vided it is installed operated maintained and tested in strict accordance with the instructions and warnings contained in this manual WARNING WARNING CAUTION Mechanical Electrical When you see this Si...

Page 3: ...ion 13 Door behaviour and Entrapment Protection inputs 14 15 Door behaviour modes 14 Setting door behaviour 14 Installing Entrapment Protection Devices 15 Additional switchgear Accessories 15 Toggle I...

Page 4: ...a two wire quick connect plug in toggle input which allows direct connection of an ex ternal devices such as a single button open close control and access control devices such as card readers keypads...

Page 5: ...ide that meets the requirements listed below Must have minimum distance of 15mm between mounting plate and door drum sprocket refer pg 6 image no 1 Must have minimum distance of 10mm between APE housi...

Page 6: ...must not be repositioned It is strongly recommended that a suitably rated lifting strap be used to raise the opener to a necessary height shown right A suitable lifting device should be con nected to...

Page 7: ...an be used to reposition the main control housing Please contact your local dealer or Chamberlain for more information Location of Controller see left Controller has 6 metres of cable with RJ45 ends r...

Page 8: ...AUTION Motor may become hot during operation Appropriate clearance and or shielding should be supplied by the in staller to ensure any cabling wiring and or other items cannot come in contact with the...

Page 9: ...the wiring rules of the country in which it is installed Supply connection for three phase builds with neutral Models ML5053 ML5103 MH5103 ML5153 Supply connection for single phase builds 3 wire confi...

Page 10: ...ve 2 0 opener identify the most appropriate entry of the MCB enclosure for your installa tion Open the MCB enclosure and fit the conduit fitting allowing enough cable to reach the controller RJ45 sock...

Page 11: ...t put the unit into limit setting mode To do this 1 While holding STOP press the SET button 3 times The LIMIT ERROR indicator will start flashing signifying limit setting mode 2 Press and hold STOP fo...

Page 12: ...final function test of the system and where present a full function test of the safety devices must be done READ CAREFULLY BEFORE SETTING LIMITS not applicable to roller shutters The eDrive 2 0 featur...

Page 13: ...l third limit extended open position The third limit is a handy option for high doors that rarely need to be fully opened The third limit is a door position above the open limit position which can be...

Page 14: ...ravel downwards while the down button is being held For details on the 3 distinct modes refer above The door must only be set to latch DOWN if there is a suitable Entrapment Protection Device installe...

Page 15: ...2 0 features constant pressure to close This means that if an Entrapment Protection Device fails the opener can still inch down unless an expansion board is used Additional switchgear eg dedicated op...

Page 16: ...uggable terminal block see diagram on page 17 Transmitter Management If transmitter management is required you will need a Grifco STAR1000EVO This accessory will allow up to 1000 identified users to b...

Page 17: ...behaviour DIP Switches 13 Mains Motor connection tables 5 Transformer 14 Controller cable entry typical 6 Toggle Input 15 HHDT input diagnostic tool 7 Expansion Board Input 16 Mains power cable entry...

Page 18: ...18 ACCESSORIES Call 1800 GRIFCO for assistance with any of the above accessories or other enquiries...

Page 19: ...ER Press and hold the SET button then whilst holding press the DOWN button 3 times green status light ON solid Press the UP button to increase the auto timer to close setting in 10 second incre ments...

Page 20: ...hilst holding press STOP 5 times green status light will light then continue flashing Indicating learn mode Press the desired WIRELESS ACCESSORY BUTTON to learn door 1 orange limit light will flash fa...

Page 21: ...IED OUT BY A QUALIFIED TECHNICIAN To view total cycles limits must be set Drive to door to closed limit Press and hold CLOSE for 10 seconds After 10 seconds and while still holding CLOSE press and rel...

Page 22: ...le Replace APE cable 10 Under speed error Extreme load on door Check for objects causing interference to door operation Check door installation Check for damage to motor Upgrade to a larger opener 12...

Page 23: ...oes the orange light start flashing after third press of the set button YES But green status light starts to flash x times while attempting to set upper limit Refer Troubleshooting pg 22 NO Ensure all...

Page 24: ...efect arising under or out of any exclusion detailed below such that the claim is not covered under this Chamberlain Limited Warranty we may subject to your other rights and remedies as a consumer cha...