13
OPERATION
To operate the door
Press the UP button on the controller to open the door, press and hold DOWN to close. For optional behavior refer to
Setting
door behaviour
on the next page.
Manual operation
The hand chain provided allows manual operation of the door at all times when the motor is not in use.
Warning!
Use of the
hand chain during powered operation of the door may result in damage to equipment or injury to the user. Ensure power is shut
off before using manual chain.
Basic installation of the 2.0 Commercial Door Opener is now complete
Please refer to the following pages for further installation instructions of optional eDrive +2.0
features and / or accessories
Optional third limit (extended open position)
The third limit is a handy option for high doors that rarely need to be fully opened. The third limit is a door position above the
open limit position which can be accessed when needed. Having this upper stopping position allows a mid height limit to be set
as a first opening point, while a further press of the open button takes the door to a higher set position.
Setting the third limit
Once the Open and Closed limits have been set:
1.
Position the door at the open limit position
2.
While holding the UP button, press the SET button 3 times.
The LIMIT ERROR indicator will flash
3.
Now open the door further until the door is in the desired extended open position
4.
Press SET to save this as the extended open position.
The LIMIT ERROR indicator will quickly flash then go out
Accessing the third limit:
1.
Open door to first upper limit
2.
Press the UP button