Controller and MCB button reference
1.
UP
—Moves the door upwards
2.
DOWN
—Moves the door downwards
3.
STOP
—Stops the door
4.
SET
—Used primarily to set limits
5.
POWER ON
—Shows when the unit is mains powered
6.
STATUS
—Shows the status of the unit
7.
LIMIT ERROR
—When lit indicates limits are not set
8.
LRN
—Enables learning of new remotes
9.
RST
—Reset board. Hold this button for 10 seconds to
erase and force re-learn of safety Entrapment
Protection Devices.
Controller
Figure 2. Lower Right corner of 2.0 MCB
AUTO CLOSE & WIRELESS ACCESSORY SET UP
8
9
Action
Button Sequence
SET AUTO TIMER TO CLOSE ( no
expansion board fitted) FROM THE
CONTROLLER
Press and hold the
SET
button, then whilst holding press the
DOWN
button 3 times
(
green
status light ON solid)
Press the
UP
button to increase the auto-timer to close setting in 10-second incre-
ments
Press the
DOWN
button to decrease the auto-timer to close setting in 10-second
increments
Note: the
green
light will flash according to the number of 10-second increments
have been set, then goes back to solid ON. For example, a 5-minute auto-close will
be set by increasing the increments until the
green
light flashes 30 times
Press
SET
to accept setting and exit learn mode
Note: To cancel the Auto-timer-to close function, enter the learn mode and press
the
DOWN
button until the number of 10-second increments is ZERO. The
green
light will flash repeatedly to indicate the function has been reset, then return to
solid ON
Press STOP to exit