59
LED A
LED B
LED C
Error Message
ON
ON
OFF
High Internal Temperature
ON
OFF
ON
GFCI Detection Failed
OFF
ON
ON
Bus Failed
Blink
Blink
Blink
Arcing Fault Detected (AFD)
Blink
OFF
OFF
Isolation Fault (< 2.0MΩ)
OFF
Blink
OFF
Leakage Current High
OFF
OFF
Blink
Cooling Fan(s) Failed
Note
:
Blinking means LEDs on for 0.5 seconds and off for 0.5 seconds.
10.2 LED Panel + 7-Segment Display (Solution B)
This is the optimal selection of E-Series between features and price. There is a
screen consisted of 7 segments in addition to the LED panel from Ch.10.1. The
LED panel has three LED lights and one button. When fault occurs, one or two or
three LED lights will be on blinking.
10.2.1 Stand-by Mode
The 7-segment display screen enters stand-by mode when inverter receives no
DC power coming from solar panels or internal communication fault occurs.