GREISINGER GMH 3330 Operating Manual Download Page 8

H40.0.01.6C-09 

Operating Manual GMH 3330 

Page 8 of 16

 

 

 

’AVG’:  Selection of Averaging Proceedings for Flow 

Measurement  

(only STS005/020)

 

 

Cont: 

continuous averaging

 - the average value calculated from 

the measurements conducted during the averaging period will be 
displayed.

 

 

Hold: 

press key for averaging

 - flow measurements will be taken during 

the averaging period, then the average value will be calculated and 
displayed till the next flow measurement is started. 

 

 

’t.AVG’: Setting of Averaging Period 

 

(only STS005/020)

 

 

1..30: 

Time for averaging (in seconds) during flow measuring

 

 

’Unit’:  Selection of Temperature Unit 

 

 

°C: 

All temperature values in degrees Celsius

 

°F: 

All temperature values in degrees Fahrenheit

 

  

’Offset T1’: Zero Displacement of Sensor Tempera-

ture T1 

 

(only TFS0100)

 

 

 

-10.0°C...10.0°C  

or  

-18.0°F...18.0°F: 

The zero point of the measurement of T1 will be 
displaced by this value. 

off: 

Zero point displacement is deactivated (=0.0°)

 

 

 

’Offset T2’: Zero Displacement of Temperature T2 

 

 

 

-10.0°C...10.0°C 

bzw.  

-18.0°F...18.0°F: 

The zero point of the measurement of T2 will be 
displaced by this value. 

off: 

Zero point displacement is deactivated (=0.0°)

 

 

’Corr’:  Selection of Display Correction Factor 

 

 

1.001...1.200: 

The temperature value (referring to 0°C or. 32°F) will be 
multiplied by this factor. 

off: 

Factor is deactivated (=1.000)

 

 

’Power.off’: Selection of Power-Off Delay

 

 

1...120

:

 

Power-off delay in minutes. Device will be automatically 
switched off as soon as this time has elapsed if no key is 
pressed/no interface communication takes place. (automati-
cally deactivated for cyclic loggers) 

off: 

automatic power-off function deactivated  
(continuous operation, e.g. in case of mains operation) 

 

’Address’: Selection of Base Address

 

 

01, 11, 

21, …, 91: 

Base address for interface communication. Channel 
1 will be addressed by the set base address, chan-
nel 2 to 6 will have the following addresses. 
(Example: base address 21 - channel 1 = 21, chan-
nel 2 = 22, ..., channel 6 = 26)

 

Using the interface converter GRS3105 it is possible to connect several devices to a single interface. As 
a precondition the base addresses of all devices must not be identical. In case several devices are con-
nected via one interface make sure to configurate the base addresses accordingly.  

r.H.

T d

T 2

T d

m/s

kJ/kg

AL

L o g g

T 1

Co rr

CAL

max

min

2

5

r.H.

T d

T 2

T d

m/s

kJ/kg

AL

L o g g

T 1

Co rr

CAL

max

min

2

5

°C

r.H.

T d

T 2

T d

m/s

kJ/kg

AL

L o g g

T 1

Co rr

CAL

max

min

2

5

°C

r.H.

T d

T 2

T d

m/s

kJ/kg

AL

L o g g

T 1

Co rr

CAL

max

min

2

5

°C

r.H.

T d

T 2

T d

m/s

kJ/kg

AL

L o g g

T 1

Co rr

CAL

max

min

2

5

r.H.

T d

T 2

T d

m/s

kJ/kg

AL

L o g g

T 1

Co rr

CAL

max

min

2

5

r.H.

T d

T 2

T d

m/s

kJ/kg

AL

L o g g

T 1

Co rr

CAL

max

min

2

5

r.H.

Td

T2

Td

m/s

kJ/kg

AL

Logg

T1

Corr

CAL

max

min

2

5

Summary of Contents for GMH 3330

Page 1: ...93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Digital Precision Hand held Measuring Device For Atmospheric Humidity Temperature Dew Point Dew Point Distance Enthalpy and Flow...

Page 2: ...COMBINATION MEASURING SENSOR TFS0100 9 7 MEASUREMENTS USING FLOW MEASURING PROBES STS005 STS020 10 8 NOTES TO SPECIAL FUNCTIONS 11 8 1 ZERO DISPLACEMENT OFFSET 11 8 2 DISPLAY CORRECTION FACTOR CORR 1...

Page 3: ...ombined with the combined measuring probe TFS 0100 is designed for room climate meas urements This includes gauging of atmospheric humidity temperature dew point dew point distance and enthalpy Togeth...

Page 4: ...n lead to malfunctions or destroying of the device and the connected devices This device must not be run with a defective or damaged power supply unit Danger to life due to electrical shock 4 Do not u...

Page 5: ...g 4 1 Display Depending on the measuring probes sensors connected the following measuring results can be displayed TFS 0100 Main display r H relative atmospheric humidity in Secondary display possible...

Page 6: ...ing press Menu for 2 sec configuration menu is activated Store Quit Measurement Hold current measuring value HLD in display for flow meas in AVGHold mode start new measurement or handling of logger fu...

Page 7: ...tc The device with pop up clip at position 90 can be set up on a table etc The device with pop up clip at position 180 can be suspended from a screw or the magnetic holder GMH 1300 Device attached to...

Page 8: ...ll be multiplied by this factor off Factor is deactivated 1 000 Power off Selection of Power Off Delay 1 120 Power off delay in minutes Device will be automatically switched off as soon as this time h...

Page 9: ...ergy con tent of air with a relative humidity of 0 and 0 C is 0kJ kg The warmer the air the higher the relative hu midity the higher the energy content Therefore more energy is required to heat up hum...

Page 10: ...tions tend to be quite high To be able to display a stable measur ing value two averaging functions have been integrated in the instrument Continuous Averaging The average value displayed has been cal...

Page 11: ...sses of all devices must not be identical In case several devices will be connected via one interface make sure to configurate the base addresses accordingly Channel 1 will be addressed by the base ad...

Page 12: ...values a stable value has been de tected and can be taken over by means of the Store key key 6 Then the next calibration step will be displayed 3 Calibration point 2 Put sensor into suitable calibrat...

Page 13: ...cable defective replace Values below measuring range check are there any values below the measuring range specified meas value too low Sensor cable defective replace System fault switch on again if fa...

Page 14: ...Windows 7 Windows 8 8 1 Windows 10 Programming examples Visual Basic 4 0 Delphi 1 0 The following interface functions will be supported Channel Dll Code Name function 1 2 3 4 5 6 x x x x x x 0 Read n...

Page 15: ...lip for table top or sus pended use Weight approx 160 g Interface serial interface 3 5mm jack serial interface can be connected to RS232 or USB inter face of a PC via electrically isolated interface a...

Page 16: ...dequate transport package for reshipment especially for fully functional devices Please make sure that the device is protected in the package by enough packing materials 13 2 Disposal instructions Bat...

Reviews: