2.3  Safety guidelines 

This device has been designed and tested in accordance with the safety regulations for electronic de-
vices. 
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety meas-
ures and special safety advises given in this manual will be adhered to when using the device. 

1.  Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected 

to any other climatic conditions than those stated under "Specification". 
If the device is transported from a cold to a warm environment condensation may cause in a failure of 
the function. In such a case make sure the device temperature has adjusted to the ambient tempera-
ture before trying a new start-up. 

2.    

 

If there is a risk whatsoever involved in running it, the device has to be switched off im-
mediately and to be marked accordingly to avoid re-starting. 
Operator safety may be a risk if:  
- there is visible damage to the device 
- the device is not working as specified 
- the device has been stored under unsuitable conditions for a longer time. 
In case of doubt, please return device to manufacturer for repair or maintenance. 

3.  When connecting the device to other devices the connection has to be designed most thoroughly as 

internal connections in third-party devices (e.g. connection GND with protective earth) may lead to un-
desired voltage potentials that can lead to malfunctions or destroying of the device and the connected 
devices. 
 

This device must not be run with a defective or damaged power supply unit.  
Danger to life due to electrical shock!  

 

4. 

 

 

Do not use these products as safety or emergency stop devices or in any other applica-
tion where failure of the product could result in personal injury or material damage. 
Failure to comply with these instructions could result in death or serious injury and mate-
rial damage.

 

 

  

 

3  Product Specification 

3.1  Scope of supply 

The scope of supply includes:  

  Device GMH 3330, incl. 9V battery block 
  Operation manual 

 

3.2  Operation and maintenance advice 

• 

Battery operation: 
If ‘bAt’ is shown in the lower display the battery has been used up and needs to be replaced. However, 
the device 

will operate correctly for a certain time. If ‘bAt’ is shown in the upper display the voltage is 

too low to operate the device; the battery has been completely used up.  

The battery has to be taken out, when storing device above 50 °C.  
We recommend taking out battery if device is not used for a longer period of time. 
After recommissioning the real-time clock has to be set again.  

 

• 

Mains operation with power supply

 

When using a power supply please note that operating voltage has to be 10.5 to 12 V DC. 
Do not apply overvoltage!! Cheap 12V-power supplies often have excessive no-load volt-
age.  We, therefore, recommend using regulated voltage power supplies.  
 

Trouble-free operation is guaranteed by our power supply GNG10/3000. 
Prior to connecting the power supply to the mains makes sure that the operating voltage stated at the 
power supply is identical to the mains voltage. 

       

_

DANGER

 

 

       

_

DANGER

 

 
 

       

_

DANGER

 

 
 
 

Summary of Contents for GMH 3330

Page 1: ...93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Digital Precision Hand held Measuring Device For Atmospheric Humidity Temperature Dew Point Dew Point Distance Enthalpy and Flow...

Page 2: ...COMBINATION MEASURING SENSOR TFS0100 9 7 MEASUREMENTS USING FLOW MEASURING PROBES STS005 STS020 10 8 NOTES TO SPECIAL FUNCTIONS 11 8 1 ZERO DISPLACEMENT OFFSET 11 8 2 DISPLAY CORRECTION FACTOR CORR 1...

Page 3: ...ombined with the combined measuring probe TFS 0100 is designed for room climate meas urements This includes gauging of atmospheric humidity temperature dew point dew point distance and enthalpy Togeth...

Page 4: ...n lead to malfunctions or destroying of the device and the connected devices This device must not be run with a defective or damaged power supply unit Danger to life due to electrical shock 4 Do not u...

Page 5: ...g 4 1 Display Depending on the measuring probes sensors connected the following measuring results can be displayed TFS 0100 Main display r H relative atmospheric humidity in Secondary display possible...

Page 6: ...ing press Menu for 2 sec configuration menu is activated Store Quit Measurement Hold current measuring value HLD in display for flow meas in AVGHold mode start new measurement or handling of logger fu...

Page 7: ...tc The device with pop up clip at position 90 can be set up on a table etc The device with pop up clip at position 180 can be suspended from a screw or the magnetic holder GMH 1300 Device attached to...

Page 8: ...ll be multiplied by this factor off Factor is deactivated 1 000 Power off Selection of Power Off Delay 1 120 Power off delay in minutes Device will be automatically switched off as soon as this time h...

Page 9: ...ergy con tent of air with a relative humidity of 0 and 0 C is 0kJ kg The warmer the air the higher the relative hu midity the higher the energy content Therefore more energy is required to heat up hum...

Page 10: ...tions tend to be quite high To be able to display a stable measur ing value two averaging functions have been integrated in the instrument Continuous Averaging The average value displayed has been cal...

Page 11: ...sses of all devices must not be identical In case several devices will be connected via one interface make sure to configurate the base addresses accordingly Channel 1 will be addressed by the base ad...

Page 12: ...values a stable value has been de tected and can be taken over by means of the Store key key 6 Then the next calibration step will be displayed 3 Calibration point 2 Put sensor into suitable calibrat...

Page 13: ...cable defective replace Values below measuring range check are there any values below the measuring range specified meas value too low Sensor cable defective replace System fault switch on again if fa...

Page 14: ...Windows 7 Windows 8 8 1 Windows 10 Programming examples Visual Basic 4 0 Delphi 1 0 The following interface functions will be supported Channel Dll Code Name function 1 2 3 4 5 6 x x x x x x 0 Read n...

Page 15: ...lip for table top or sus pended use Weight approx 160 g Interface serial interface 3 5mm jack serial interface can be connected to RS232 or USB inter face of a PC via electrically isolated interface a...

Page 16: ...dequate transport package for reshipment especially for fully functional devices Please make sure that the device is protected in the package by enough packing materials 13 2 Disposal instructions Bat...

Reviews: