MG510R Calibration
15
W450256 Rev A 06/07
Menu 04 - angle sensor
This menu is used to enter the zero point and span for the angle sensor. This is done using the digital
level.
TEST
SET
Press the key adjacent to either “Menu Up” or “Menu Down” until “04 Angle Sensor” appears in the
information window at the right.
Press the key adjacent to “04 Angle Sensor” to enter the routine.
With the boom in a horizontal position, press the key adjacent to “Zero Angle? = XXX”.
TEST
SET
TEST
SET
The extension sensor is now zeroed.
Press the key adjacent to “Span Angle? X.X”.
Raise the boom until the inclinometer reads 60° or slightly higher.
Enter the value for the angle from the inclinometer. Use the keys adjacent to the numerical values at
the bottom of the window to scroll left or right and highlight each number. Use the key adjacent to
“Enter Sensor Span” to enter the number. When complete, the menu will automatically change to the
previous menu. To exit the routine without changes, press the key adjacent to “Exit”.
Note: Measurements must be entered in degrees and tenths (xx.xx). If necessary, recorded
measurements must be converted before starting.
TEST
SET
04 Angle Sensor Exit>
Enter Sensor Span [0.00 ]
<0> 1 2 3 4 5 6 7 8 9 < . -
When you have finished, press the key adjacent to “Exit” to return to the main menu.
Summary of Contents for MicroGuard 510 Retrofit
Page 1: ...MicroGuard 510 Retrofit Rated Capacity Indicator System Calibration...
Page 2: ......
Page 40: ...MG510R Calibration 36 W450256 Rev A 06 07...
Page 46: ...MG510R Calibration A 6 W450256 Rev A 06 07...
Page 54: ...MG510R Calibration B 8 W450256 Rev A 06 07...
Page 55: ......