MG510R Calibration
B-3
W450256 Rev A 06/07
start-up Problems
Condition
Corrective Action
Display unit lights and alarms are flashing; the
computer unit sounds as if it is buzzing.
Make sure the PTO is fully engaged.
•
During system setup, it is not possible to adjust the
angle sensor. The display shows “---”.
Make sure the extension reel is installed the
•
correct way up.
Make sure the extension reel signal cable is
•
correctly connected to the computer unit.
Check the extension reel voltages. Refer to
•
“Extension Reel Voltage Checks” on page A-3.
A few seconds after power up, the display shows “No
communications with MicroGuard®” in the load display
window.
Computer is possibly not running.
•
Check that the system program chip is correctly
•
inserted.
Check that all LEDs within the computer are
•
lit and that the communications LED (D6) is
flashing; If not replace system chip.