MG510R Calibration
14
W450256 Rev A 06/07
Menu 03 - Extension sensor
This menu allows for entering the zero point and span of the extension sensor that were previously
recorded in Appendix A.
TEST
SET
Press the key adjacent to either “Menu Up” or “Menu Down” until “03 Extension Sensor” appears in
the information window at the right.
Press the key adjacent to “03 Extension Sensor” to enter the routine.
Press the key adjacent to “Zero Extension? = XXX”.
TEST
SET
The extension sensor is now zeroed.
m
WaRNING
BEfoRE ExTENDING ThE BooM, MakE sURE ThE aREa aRoUND ThE CRaNE Is safE. MaNy
CRaNEs WIll TIP ovER If ThE BooM Is ExTENDED hoRIZoNTally!!
Press the key adjacent to “Span Extension? X.X”.
Full extend the boom and then enter the
value for the span. Use the keys adjacent to
the numerical values at the bottom of the
window to scroll left or right and highlight
each number. Use the key adjacent to “Enter
Sensor Span” to enter the number. When
complete, the menu will automatically change to the previous menu. To exit the routine without
changes, press the key adjacent to “Exit”.
Note: Measurements must be entered in feet and tenths (xx.xx). If necessary, recorded
measurements must be converted before starting.
TEST
SET
When you have finished, press the key adjacent to “Exit” to return to the main menu.
T
S
Summary of Contents for MicroGuard 510 Retrofit
Page 1: ...MicroGuard 510 Retrofit Rated Capacity Indicator System Calibration...
Page 2: ......
Page 40: ...MG510R Calibration 36 W450256 Rev A 06 07...
Page 46: ...MG510R Calibration A 6 W450256 Rev A 06 07...
Page 54: ...MG510R Calibration B 8 W450256 Rev A 06 07...
Page 55: ......