Greenlee Textron / Subsidiary of Textron Inc.
14
GREENLEE
FAIRMONT
HG3558B/42307 Portable Power Unit
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
Troubleshooting
Engine does not turn over.
Battery weak or dead.
Recharge or replace battery.
Battery cables corroded.
Clean battery cable terminals or
replace cables.
Electrical short, broken wire or loose
Check wires and connections.
connection.
Repair or replace.
Engine starter inoperative.
Repair or replace starter.
See engine operator’s manual.
Engine turns over, but does
No fuel in tank.
Fill fuel tank.
not start.
ON/OFF switch in the OFF position.
Move switch to the ON position.
Flow ON/OFF handle in the ON
Move handle to the OFF position.
position.
Electrical short, broken wire or loose
Check wires and connections.
connection.
Repair or replace.
See engine operator’s manual.
Engine lacks power, runs rough,
See engine operator’s manual.
backfires, etc.
Tool used with power unit is
Flow ON/OFF valve in the OFF position.
Move flow ON/OFF valve to ON
inoperative.
position.
Tool is a Closed-Center system type.
Use only Open-Center system tools.
No hydraulic fluid in system or fluid
Check fluid level. Fill to FULL mark.
level low.
Check system for leaks.
Incorrect hydraulic fluid viscosity.
Use fluid viscosity recommended.
See Recommended Hydraulic Fluids.
Hydraulic filter needs service.
Replace hydraulic filter.
Power unit components (pump, valve,
Repair or replace components.
etc.) worn or damaged.
Engine output insufficient. Engine
See engine operator’s manual.
needs adjustment, tune-up, etc.
PROBLEM
PROBABLE CAUSE
POSSIBLE REMEDY