Electric Air-Conditioning Unit Green GT790 12.000BTU 24V - DS540059  

Electric Air-Conditioning Unit Green GT790 12.000BTU 12V - DS630051

Electric Air-Conditioning Unit Green GT790 12.000BTU 24V - DS540059  

Electric Air-Conditioning Unit Green GT790 12.000BTU 12V - DS630051

MAIN COMPONENTS OF 

THE AIR-CONDITIONING 

SYSTEM

CONTROLLING 

AND BOARD 

FUNCTIONS

Internal part  

Evaporator Unit

External part

Condenser Unit

1.

2.

Air inlet

Air outlet

Air inlet

Air outlet

Size: 460 x 160 x 320mm

Size: 660 x 490 x 210mm

Display

Display
• 

On/Off

- Press to turn on and off.

• 

Temperature Configuration

- Press “TEMPERATURE” to adjust tempera-

ture after you turned on the Unit;

- Now, press “TEMPERATURE” again for 

(DOWN) or “SPEED” for (UP) to adjust 

temperature (12°C-32°C).

• 

Speed Configuration

- Press “SPEED” to define the speed after you 

turned on the System;

- Now, press “TEMPERATURE” again for 

(DOWN) or “SPEED” for (UP)  to adjust 

speed   (8 speeds).

• 

Tension Configuration

- Press “ON/OFF” three times to access the 

tension adjustment, press “TEMPERA-

TURE” again for (DOWN) or “SPEED” for 

(UP)  to adjust tension.

• 

Clear Failures

- Failures are removed when the unit is 

restarted.

Remote Control
• 

On/Off

- Press to turn on and off.

• 

Temp + / -

- Controls the temperature.

• 

Speed + / -

- Controls the speed.

• 

26 °C

- Adjusts to 26 °C.

• 

Strong

- Increases to maximum power.

• 

Standard

- Standard performance.

• 

Sleep

- Economical mode.

*

Remote control battery, not included

Summary of Contents for DS540059

Page 1: ... 12V Electric Air Conditioning Unit Green GT790 12 000BTU 12V Caja Evaporadora Eléctrica Green GT790 12 000BTU 12V Leia o manual com atenção antes de instalar utilizar o produto Read this manual carefully before installing using the product Antes de la instalación y el uso del producto lea atentamente este manual MANUAL DE USO E DE INSTALAÇÃO USER MANUAL AND INSTALLATION HANDBOOK INSTRUCCIONES DE ...

Page 2: ...s 15 Technical specification 16 Internal board error code Evaporator Unit 17 Board error codes 19 Installation instructions 20 Maintenance 22 Warranty and services 23 Indicated products for maintenance 34 Warranty request form 35 Componentes principales del aire acondicionado 24 Funciones de control y panel 25 Especificaciones técnicas 26 Código de error en el panel interno Caja Evaporadora 27 Fal...

Page 3: ...C 32 C Ajuste de velocidade Após ligar pressione SPEED para definir a velocidade Pressione novamente a função TEMPERA TURE para baixo ou SPEED para cima para ajustar a velocidade 8 velocidades Configuração de tensão Após ligar pressione ON OFF 3 vezes para acessar os ajustes de tensão pressione TEM PERATURE para baixo ou SPEED para cima para ajustar tensão Limpeza de falhas As falhas são removidas...

Page 4: ... ao normal H23 A falha do sensor de saída de ar in dica que o modo pode ser alterado após retornar ao normal E04 Sensor de temperatura do tubo ar de saída E05 Compressor está superaquecendo Assim que o Compressor retornar a uma temperatura normal automaticamente volta a funcionar E06 Verifique se o circuito saindo do Compressor para o Eletroventilador do Condensador está aberto E07 Verifique possí...

Page 5: ...ficiente Selecione o modo refrigeração e em seguida selecione a temperatura e velocidade apropriadas Verifique se há obstruções nas saídas e ou entradas de ar Verifique se a superfície do Condensador está suja Verifique se tem Gás Refrigerante suficiente no sistema e se as linhas de alta e baixa voltagem estão normais Água na superfície da Caixa Evaporadora A formação de gotas de água na saída de ...

Page 6: ...inutos certifique se de que todo o ar Depois da Unidade Condensadora e da Unidade Evaporadora fixadas conecte os tubos e instale a Válvula de Expansão Durante a instalação observe se a parte de junção da válvula e do tubo de conexão estão limpos Verifique se o anel de vedação não está danificado e aplique a quantidade adequada de Gás Refrigerante antes de instalar Conexão dos cabos de alimentação ...

Page 7: ...loque baterias no controle remoto faça uma inspeção e ligue o aparelho Esse produto vem acompanhado de um manual de instalação oferecido pela GREEN a ser rigorosamente seguido pelos instaladores e usuários Caso haja falha por parte do usuário e ou imprudência por parte do instalador de seguir as instruções contidas nesse manual qualquer dano acidente e ou problema proveniente dessas falhas é de to...

Page 8: ...n Press TEMPERATURE to adjust tempera ture after you turned on the Unit Now press TEMPERATURE again for DOWN or SPEED for UP to adjust temperature 12 C 32 C Speed Configuration Press SPEED to define the speed after you turned on the System Now press TEMPERATURE again for DOWN or SPEED for UP to adjust speed 8 speeds Tension Configuration Press ON OFF three times to access the tension adjustment pr...

Page 9: ...utlet sensor failure which indi cates the mode might alter after return ing to normal function E04 Temperature sensor of the pipe Air Outlet E05 Compressor is overheating and as soon as the Compressor s temper ature goes down it returns to normal function E06 Check if the circuit coming from the Compressor in direction to the Con denser Fan is open E07 Check for a possible short circuit between th...

Page 10: ... available solutions 5 INCIDENT SOLUTION The system is not properly cooling First select the cooling mode and then select the appropriate temperature and speed Check for any obstruction at the air in outlet Check for any dirt at the Condenser s surface Check for enough refrigerant quantity at the system and if low high tension are normal Water on the Evaporator Unit s surface Formation of water dr...

Page 11: ...s are not inverted If the power cable length is too short you might extend it for a maximum of 1 5m and the connector must be protected waterproofed 6 IMPORTANT The air conditioning power cable shall be connected to the battery s positive and negative terminal connectors only after the Evaporator Unit and the Condens er Unit are installed And the total length of the power cable shall NOT be longer...

Page 12: ...it on This product comes with a user manual installation handbook which is offered by GREEN and SHALL be strictly followed by its installation staff and or users In case of user s misusage and or because of recklessness at installation due to foreseen instructions of this manual have not been followed any damage accident and or failure therefore caused to the product in question is of their fully ...

Page 13: ...peratura después de encender Después presione TEMPERATURE abajo o SPEED arriba nuevamente para el ajuste de la temperatura 12 C 32 C Ajuste de velocidad Presione SPEED para configurar la velocidad después de encender Después presione el botón TEMPERATURE abajo o SPEED arriba nuevamente para ajustar la velocidad 8 velocidades Ajuste de voltaje Después de encender presione ON OFF 3 veces para entrar...

Page 14: ...lidad H23 La falla del sensor de salida de aire indica que el modo se puede cambiar después de volver a la normalidad E04 Sensor de temperatura del tubo aire de salida E05 El compresor se está sobrecalentan do Tan pronto como el compresor vuelve a una temperatura normal au tomáticamente comienza a funcionar nuevamente E06 Verificar si el circuito que sale del compresor al electroventilador del con...

Page 15: ...temente Seleccione el modo de enfriamiento y luego seleccione la temperatura y velocidad adecuadas Compruebe si hay obstrucciones en las salidas y o entradas de aire Compruebe si la superficie del condensador está muy sucia Compruebe que haya suficiente gas refrigerante en el sistema y que las líneas de alta y baja tensión estén en condiciones normales Agua sobre la superficie de la Caja Evaporado...

Page 16: ...nsadora y la Caja Evaporadora estén conectadas conecte los tubos e instale la válvula de expansión Durante la instalación asegúrese de que la válvula y las juntas de la tubería de conexión estén limpias Compruebe que la junta no esté dañada y aplique la cantidad adecuada de gas refrigerante antes de instalar Conexión de los cables de alimentación Todos los cables de conexión eléc trica de la Caja ...

Page 17: ... en el control remoto haga una inspección y encienda el dispositivo Este producto va acompañado de un manual de instalación ofrecido por GREEN para ser seguido estrictamente por instaladores y usuarios En caso de falla por parte del usuario y o imprudencia por parte del instalador de seguir las instrucciones contenidas en este manual cualquier daño accidente y o problema que surja de estas fallas ...

Page 18: ...Estado State Departamento Contato Contact Contacto E mail Telefones Phones Teléfonos Nº da nota fiscal Invoice Nº Nº de Factura Data de emissão Date of Issue Fecha de Emisión Produto Product Producto Código Code Código DS630051 12V DS540059 24V Descrição do defeito Description of defect Descripción del defecto É necessário preencher todos os campos do formulário abaixo All fields are requested to ...

Page 19: ...onosco pelo telefone 55 41 3021 1358 In case of any doubts related to installation don t hesitate to call 1 321 333 0566 Si tiene alguna pregunta sobre la instalación comuníquese con nosotros al 1 321 333 0566 w w w g r e e n a c p a r t s c o m 220421 ...

Reviews: