Follow these steps:

MONTHLY MAINTENANCE (EVERY 30 DAYS)

Every 30 days we recommend you replace certain elements of the Mosquito Preventer. Ask the retailer, or place where you 

purchased your unit if they carry the Reactor Kits.

WEEKLY MAINTENANCE

Check water level of the Mosquito Preventer through the viewing window. If green the water level is good, if red more water needs

to be added to the system. To add more water remove the rain guard, lid and umbrella and then add water to the breeding zone

until the green bobber appears in the viewing window. Return the umbrella, lid and rain guard securely back onto the Mosquito 

Preventer.

Your Mosquito Preventer is now set up. The system will rinse once before starting its automatic cycling schedule.

END OF SEASON MAINTENANCE

Follow steps 1 and 3 from the monthly maintenance and remove the batteries. Wash, dry and store the Mosquito Preventer in an 

upright position and in a dry place.

1. Put Mosquito Preventer into Maintenance Mode by pressing the power button and holding it for 3-5 seconds. The light will start 

    blinking, and the valve will open and drain the water.

2. Replace the reactor. Remove the previous month’s reactor and peel off the label on the new reactor.

3. Drain the water from the bottom by removing the grommet. When fully drained return the grommet back into the bottom. 

     *See note in WARNINGS, page 1 for draining area

4. Refill the Mosquito Preventer with 3.2L of either rain or distilled water (to prevent calcium buildup). 

5. Replace both of the landing strips and repeat step 10 of setup instructions.

Grommet

TROUBLESHOOTING

PROBLEM

INDICATES

# OF FLASHES

VALVE MOTOR

2

3

4

5

PUMP

LOW BATTERY

PCB

POSSIBLE CAUSE

SOLUTION

SOLUTION

My unit will not Start/Turn On

Batteries are dead or low

Defect in power system

Replace batteries

Contact www.greenstrikeinternational.com

Remove batteries and replace with new batteries

Contact www.greenstrikeinternational.com

Contact www.greenstrikeinternational.com

Contact www.greenstrikeinternational.com

The unit has not fully adjusted to your 

environment

Your unit may not be in the right location in

your yard

The attractant has fermented

This is normal

It may take up to 1 month to see noticeable 

results as the unit works to kill off future

mosquito generations

Move your unit in an area with lots of shade, 

wind protection and lots of vegetation

I still see lots of mosquitoes 

around my living area

There is a smell coming from 

the unit

POWER BUTTON DIAGNOSTICS

When the Mosquito Preventer encounters an error, it will stop all operations and flash the power button in a specific way to let 

the user know what part of the preventer has failed. It will flash a different number of times for each error followed by a 5 second 

pause. It will repeat this sequence until the error has been resolved and the system has been reset. To manually reset the system 

remove the batteries for 3 seconds.

See the below diagnostic errors codes, contact us at www.greenstrikeinternational.com for additional help.