©April 2017
Call Toll free at (800) 269-7130
CIR-TM6000AC-G1 Revision 1.2
3
John C. Jensen
SAFETY PRECAUTIONS
Environment
The unit is designed to function normally in an environment with a relative humidity range of 30% to 75%. The unit can be
shipped and stored in a relative humidity range of 10% to 90%. Climatic dry air may cause static electricity. During a
workout, a user may experience a shock due to a buildup of static electricity on the body and the discharge path of the unit.
If static electricity is experienced, increase humidity to a comfortable level through the use of a humidifier.
Temperature
The unit is designed to function in an environment with an ambient temperature range of 50°F (10°C) to 104°F (40°C).
The unit can be shipped and stored in an environment with an ambient temperature range of 32°F (0°C) to 140°F (60°C).
Electrical Power Requirements
The power requirements for this treadmill are a grounded, dedicated circuit rated for the following:
115 VAC, 50/60 HZ, 20A
Shock and electrocution hazard.
Connect unit to a grounded outlet.
Do not use a voltage adapter or extension cord.
Important Voltage Information
Before plugging the power cord into an electrical outlet, verify that the voltage requirements for your area match the
voltage of the treadmill that you have received. The power requirements for the treadmill include a grounded,
dedicated circuit, rated for one of the following figure. See the serial number decal for the exact voltage
requirements of your treadmill.
WARNING:
Don't attempt to use this unit with an unapproved voltage adapter. All voltage adapters
MUST
be approved and supplied by Green Series Fitness prior to use.
Don't attempt to use this unit with an extension cord which does not meet Green Series Fitness criteria of the
following; 12 gauge SO3, maximum of 25 foot length with a 20 amp rating.
Grounding Instructions
This equipment must be grounded. If it should malfunction or break down, grounding provides
a path of least resistance for electric current to reduce the risk of electric shock.
This equipment is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Please make sure that the equipment is connected to an outlet having the same configuration as the plug. Do not use a
ground plug adapter to adapt the power cord to a non-grounded outlet.
120V EURO PLUG 208-240V
NEMA 5-20 CEE 7/7 NEMA 6-15
The power requirements for the equipment includes a grounded, dedicated circuit, rated for one of the
following:
120 VAC 5%, 60HZ and 20 amps;
208/240 VAC, 60HZ, 15 amps
240 VAC 5%, 50HZ and 15amps.
WARNING