70
HE
AT ONL
Y
C
OMBI
HE
AT ONL
Y
COMBI
Par
ameter
Par
ameter Description
Range
GMHB 125
NG
GMHB 125
LPG
GMCB 150
NG
GMCB 150
LPG
GMHB 160
NG
GMHB 160
LPG
GMCB 200
NG
GMCB 200
LPG
P01
DHW Modula
tion
(0..1)
0
0
0
0
0
0
0
0
P02
Gas T
ype Selection
(0: na
tur
al g
as; 1: LPG)
0
1
0
1
0
1
0
1
P03
Boiler se
tting
00= ins
tan
taneous c
ombi boiler
02= ins
tan
taneous c
ombi boiler with DHW micr
o t
ank
03= ins
tan
taneous c
ombi boiler with pr
e hea
t
04= only hea
ting boiler with DHW thermos
ta
t (s
ys
tem boiler 1)
05= only hea
ting boiler f
or e
xt
ernal DHW t
ank
06= boiler with DHW s
tor
ag
e t
ank
07 = Hea
ting only
08 = only hea
ting boiler
09 = s
tor
ag
e t
ank 3 (simple solar)
10 = ins
tan
taneous boiler f
or solar applic
ation
11 = ins
tan
taneous boiler f
or solar applic
ation with DHW micr
o-
tank 13 = ins
tan
taneous boiler with pr
e-hea
t f
or solar applic
ation
15= only hea
ting boiler with DHW pump f
or e
xt
ernal t
ank
16= boiler with DHW s
tor
ag
e t
ank and DHW pump with pla
te t
o
pla
te
DHW hea
t e
xchang
er
17 = S
ys
tem boiler 2 (04 without pump)
18 = only hea
ting boiler with DHW pump f
or e
xt
ernal t
ank
19= S
ys
tem boiler 3
(0..19)
8
8
0
0
8
8
0
0
P04
Manuf
actur
er in
forma
tion. Shall be se
t t
o 02. Ignor
e all
other op
tions.
(0..15)
2
2
2
2
2
2
2
2
P05
Manuf
actur
er in
forma
tion. Shall be se
t t
o 04. Ignor
e all
other op
tions.
(0..15)
4
4
4
4
4
4
4
4
P06
Out
door r
ese
t input c
on
figur
ation
00= with an out
door sensor c
onnect
ed, the out
door
temper
atur
e
value help
s t
o c
alcula
te the supply t
emper
atur
e se
tpoin
t
01= with an out
door sensor c
onnect
ed, the displa
y sho
w
s
the out
door
temper
atur
e v
alue (no in
fluence on supply t
emper
atur
e)
02= (R
eser
ved, not used)
03= hea
ting r
eques
t input (e.
g. t
elephonic trig
ger)
04 = Lo
w t
emper
atur
e sa
fe
ty thermos
ta
t
05 = (R
eser
ved, not used)
(0..5)
0
0
0
0
0
0
0
0
10.3.6 Description Of Parameters
10 - OPERATING INSTRUCTIONS
PN 240012363 REV. B [03/29/2019]