FIGURE 6-5 SIDE WALL COAXIAL VENTING
FIGURE 6-6 ROOF MOUNT COAXIAL VENTING
2” (50 mm)
X
Min. 8" (181 mm)
Max. 14" (356 mm)
Maintain 12"(305 mm)
US (18"(457 mm)
Canada) clearance
above highest
anticipated snow level
24" (610 mm) above
roof or ground
Ground
Anticipated
Snow Line
Maintain 12"(305 mm)
US (18"(457 mm)
Canada) clearance
above highest
anticipated snow level
24" (610 mm) above
roof or ground
Anticipated
Snow Line
18" Vertical
Clearance to
ventilated soffit
FIGURE 6-4 - COAXIAL VERTICAL EXHAUST (MULTIPLE
BOILERS)
12" (305 mm)
Minimum Separation
Manufacturer
Recommends
Greater Separation
6 - COMBUSTION AIR AND VENT PIPING
PN 240012363 REV. B [03/29/2019]