TO TURN ON THE HEATER
1. Turn on the valve on the gas supply cylinder completely.
2. Press lightly and turn the variable control knop to PILOT position
(counter-clockwise 90
o
).
3. Press down the variable control knob and hold for 30 seconds. While holding
down the variable control knob, press the ignite button several times until the
pilot flame lights. Release the variable control knob after the pilot flame lights.
Note:
• If a new tank has just been connected, please allow at least one minute for
the air in the gas pipeline to purge out through the pilot hole.
• When lightning the pilot frame make sure that the variable knob is
continuously pressed down while pressing the ignite button. Variable control
knob can be released after the pilot flame lights.
• Pilot flame can be watched and checked from the small round window with
sliding lid located at the bottom of the flame screen (to the left or right side of
the controller).
• If the pilot flame does not light or it goes out, repeat step 3.
4. After the pilot flame lights, turn the variable control knob to maximum position
and leave it there for 5 minutes or more before turning the knob to desired
temperature position.
TO TURN OFF THE HEATER
1. Turn the variable control knob to PILOT
position.
2. Then press lightly and turn the variable control
knob to OFF position.
3. Turn off the valve on the gas supply cylinder
completely.
Operation and storange
Variable control knob
Igniter
lgniter
Pilot
Off
Hi
Lo
Storage
1. Always close the gas valve of the gas cylinder after use or in case of a
disturbance.
2. Remove pressure controller and the hose.
3. Check the tightness of the gas valve and for damage. If you suspect a
damage, have it changed by your gas dealer.
4. Never store liquid gas cylinder in a sup-terrain, or at places without adequate
air ventilation.