background image

The refrigerant

Appliance filled 

with flammable

gas R32.

appliance, read 

Safety operation of flammable refrigerant

Before install the

manual first.

the installation 

appliance, read 

Before use the 
the owner’s ma-

nual first.

the service ma-

appliance, read 

Before repair the 

nual first.

To realize the function of the air conditioner unit, 

a special refrigerant circulates in the system. 

The used refrigerant is the fluoride R32, which 

is specially cleaned. 

The refrigerant is flammable 

and inodorous. Furthermore, it can lead to ex-

plosion under certain conditions. But the flam-

mability of the refrigerant is very low. It can be 

ignited only by fire. 

WARNING

Qualification requirement for installation 

and maintenance man

Compared to common refrigerants, R32 is a 

nonpolluting refrigerant with no harm to the 

ozonosphere. The influence upon the green- 

house effect is also lower. R32 has got very 

good thermodynamic features which lead to a 

really high energy efficiency. The units there 

fore need a less filling.

 

 (Please refer to table "a" in section of " Safety 

operation of flammable refrigerant "  for space X.) 

Appliance filled with flammable gas R32. For 

repairs, strictly follow manufacturer’s instructions 

only . Be aware that refrigerants may not contain 

an odour.  Read specialist’s manual.

All the work men who are engaging in the refrig-

eration system should bear the valid certification 

This appliance is not intended for use by persons

able refrigerant.

It can only be repaired by the method suggested 

by the equipment’s manufacturer.

awarded by the authoritative organization and 

the qualification for dealing with the refrigeration 

system recognized by this industry. If it needs

other technician to maintain and repair the appl-

iance, they should be supervised by the person 

who bears the qualification for using the flamm-

 (including children) with reduced physical, sensory 

or

 

n

a

 

e

c

n

e

ir

e

p

x

e

 f

o

 

k

c

a

r

o

 ,

s

e

it

il

i

b

a

p

a

c

 l

a

t

n

e

m

knowledge, unless they have been given superv-

ision or instruction concerning use of the applia-

nce by a person responsible for their safety. 

Children should be supervised to ensure that th-

ey do not play with the appliance.   

 

operating electric heater.) Do not pierce or burn. 

Appliance shall be installed, operated and stored 

in a room with a floor area larger than X

m .

2

R32: 675 

Do not use means to accelerate the defrosting 

process or to clean, other than those recomm-

ended by the manufacture. Should repair be 

necessary, contact your nearest authorized 

Service Centre. Any repairs carried out by unq-

ualified personnel may be dangerous. The app-

liance shall be stored in a room without contin-

uously 

operating ignition sources. (for example: 

open flames, an operating gas appliance or an

This marking indicates that this prod-

uct should not be disposed with other

house hold wastes. To prevent possib-

le harm to the environment or human

health from uncontrolled waste throu-

ghout the EU. To prevent possible harm to the en-

vironment or human health. 

From uncontrolled waste disposal, recycle it res-

mental safe recycling. 

If it needs to install, move or maintain the air co-

nditioner, please contact dealer or local service

center to conduct it at first. Air conditioner must 

be installed, moved or maintained by appointed

unit. Otherwise, it may cause serious damage or

personal injury or death.     

ponsibly to promote the sustainable reuse of 

material resources. To return your used device, 

please use the return and collection systems or

contact the retailer where the product was pur-

chased. They can take this product for environ-

Summary of Contents for U-Crown GWH09UB-K6DNA4A/O

Page 1: ...tructions Split Air Conditioner Notice Actual product may be different from graphics please refer to actual products Thank you for choosing our product Please read this Owner s Manual carefully before...

Page 2: ...C S6DBA1A O GWH12QB K6DNB4Y O GWH12QC K6DNA1C O GWH12QC K6DNA1D O GWH12QC K6DNA5X O GWH12YC K6DNA1A O GWH12YC K6DNA1Z O GWH12YD S6DBA2A O GWH12UB K6DNA4A O GWC18ACD K6DNA1D O GWH18ACE S6DBA1A O GWH18Q...

Page 3: ...easons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information use...

Page 4: ...cian to maintain and repair the appl iance they should be supervised by the person who bears the qualification for using the flamm including children with reduced physical sensory or d n a e c n e i r...

Page 5: ...erant If you should cut or weld the refrigerant system pipes in the process of maintaining please foll ow the steps as below c Vacuuming d e Cutting or welding Clean it with N2 gas f Carry back to the...

Page 6: ...air conditioner Unstable power supply or incorrect wiring may result in electric shock fire hazard or malfunction Please in stall proper power supply cables before using the air conditioner The ground...

Page 7: ...so that the plug is accessible For the air conditioner with plug the plug should be reachable after finishing installation For the air conditioner with out plug an circuit break must be installed in t...

Page 8: ...d by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose socket Otherwise it may cause fire hazard Do disconne...

Page 9: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Page 10: ...5 Parts name Outdoor Unit Notice Actual product may be different from above graphics please refer to actual product air inlet air outlet...

Page 11: ...pressure side gas valve immediately stop the unit and disconnect power Please note that the time for refrigerant recovery should not exceed 1 minute If refrigerant recovery takes too much time air ma...

Page 12: ...he place with high frequency devices such as welding machine medical equipment The place near coast area The place with oil or fumes in the air 8 The temperature of refrigerant circuit will be hi with...

Page 13: ...tuation 1 1 Step 3 fix outdoor unit pipe joint Select installation location according to As for the shape of drainage joint please refer to the current product Do not install the drainage joint in the...

Page 14: ...g terminal according to the color fix them with screws Notice Step 6 neaten the pipes Fix the power connection wire and signal con trol wire with wire clip only for cooling and h eating unit Notice 1...

Page 15: ...uum pump Remove the valve caps on the liquid valve and It may cause insufficient cooling heating capacity 1 1 2 5 Remove the piezometer open the valve core Reinstall the handle It may cause insufficie...

Page 16: ...on pipe of 7 5m and 8m the min length of con nection pipe is 3m Max length of connection pipe is shown as below 4 1 2 The calculation method of additional refrigerant oil and refrigerant charging amou...

Page 17: ...s from getting into the pipe is any blemish expand the port again acco rding to the steps above 52 32 32 23 27 24 18 Outdoor side DB WB C cooling Maximum Notice The operating temperature range outdoor...

Page 18: ...C K6DNA1D GWC18ACD K6DNA1D Notice The operating temperature range outdoor tempera ture for cooling only unit is 15 C 48 C For model GWC24ACE K6DNA1A 54 32 32 23 27 24 18 Outdoor side DB WB C Maximum c...

Page 19: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66160000581 Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail global cn gree com Web www gree com...