Explanation of Symbols

WARNING
CAUTION

NOTICE

1.Damage the product due to improper use or misuse of the product;

2.Alter, change, maintain or use the product with other equipment without abiding

by the instruction manual of manufacturer;

3.After verification, the defect of product is directly caused by corrosive gas;

4.After verification, defects are due to improper operation during transportation of

product;

5.Operate, repair, maintain the unit without abiding by instruction manual or related

regulations;

6.After verification, the problem or dispute is caused by the quality specification or

performance of parts and components that produced by other manufacturers;

7.The damage is caused by natural calamities, bad using environment or force

majeure.

Exception Clauses

Manufacturer will bear no responsibilities when personal injury or property loss is 

caused by the following reasons.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to

property.
Indicates important but not hazard-related 

 

information, used 

to indicate risk of property damage.

If it needs to install, move or maintain the air conditioner, please contact dealer 

or local service center to conduct it at first. Air conditioner must be installed, 

moved or maintained by appointed unit. Otherwise, it may cause serious damage 

or personal injury or death.

When refrigerant leaks or requires discharge during installation, maintenance, 

or disassembly, it should be handled by certified professionals or otherwise in 

compliance with local laws and regulations.

This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

Summary of Contents for U-Crown GWH09UB-K6DNA4A/O

Page 1: ...tructions Split Air Conditioner Notice Actual product may be different from graphics please refer to actual products Thank you for choosing our product Please read this Owner s Manual carefully before...

Page 2: ...C S6DBA1A O GWH12QB K6DNB4Y O GWH12QC K6DNA1C O GWH12QC K6DNA1D O GWH12QC K6DNA5X O GWH12YC K6DNA1A O GWH12YC K6DNA1Z O GWH12YD S6DBA2A O GWH12UB K6DNA4A O GWC18ACD K6DNA1D O GWH18ACE S6DBA1A O GWH18Q...

Page 3: ...easons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information use...

Page 4: ...cian to maintain and repair the appl iance they should be supervised by the person who bears the qualification for using the flamm including children with reduced physical sensory or d n a e c n e i r...

Page 5: ...erant If you should cut or weld the refrigerant system pipes in the process of maintaining please foll ow the steps as below c Vacuuming d e Cutting or welding Clean it with N2 gas f Carry back to the...

Page 6: ...air conditioner Unstable power supply or incorrect wiring may result in electric shock fire hazard or malfunction Please in stall proper power supply cables before using the air conditioner The ground...

Page 7: ...so that the plug is accessible For the air conditioner with plug the plug should be reachable after finishing installation For the air conditioner with out plug an circuit break must be installed in t...

Page 8: ...d by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose socket Otherwise it may cause fire hazard Do disconne...

Page 9: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Page 10: ...5 Parts name Outdoor Unit Notice Actual product may be different from above graphics please refer to actual product air inlet air outlet...

Page 11: ...pressure side gas valve immediately stop the unit and disconnect power Please note that the time for refrigerant recovery should not exceed 1 minute If refrigerant recovery takes too much time air ma...

Page 12: ...he place with high frequency devices such as welding machine medical equipment The place near coast area The place with oil or fumes in the air 8 The temperature of refrigerant circuit will be hi with...

Page 13: ...tuation 1 1 Step 3 fix outdoor unit pipe joint Select installation location according to As for the shape of drainage joint please refer to the current product Do not install the drainage joint in the...

Page 14: ...g terminal according to the color fix them with screws Notice Step 6 neaten the pipes Fix the power connection wire and signal con trol wire with wire clip only for cooling and h eating unit Notice 1...

Page 15: ...uum pump Remove the valve caps on the liquid valve and It may cause insufficient cooling heating capacity 1 1 2 5 Remove the piezometer open the valve core Reinstall the handle It may cause insufficie...

Page 16: ...on pipe of 7 5m and 8m the min length of con nection pipe is 3m Max length of connection pipe is shown as below 4 1 2 The calculation method of additional refrigerant oil and refrigerant charging amou...

Page 17: ...s from getting into the pipe is any blemish expand the port again acco rding to the steps above 52 32 32 23 27 24 18 Outdoor side DB WB C cooling Maximum Notice The operating temperature range outdoor...

Page 18: ...C K6DNA1D GWC18ACD K6DNA1D Notice The operating temperature range outdoor tempera ture for cooling only unit is 15 C 48 C For model GWC24ACE K6DNA1A 54 32 32 23 27 24 18 Outdoor side DB WB C Maximum c...

Page 19: ...GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66160000581 Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail global cn gree com Web www gree com...

Reviews: