22
Technical Information
Service Manual
up, the temperature will decrease 1
Ƈ
after 1
in every hour,
Ƈ
decreased, this temperature will be maintained.
(2) Under the initial presetting temperature17
Ƈ
-20
Ƈ
, after Sleep function started
up, the temperature will decrease 1
Ƈ
in every hour, after 2
Ƈ
decreased, this temperature will be maintained.
(3) Under the initial presetting temperature 21
Ƈ
-27
Ƈ
, after Sleep function started
Sleep 3 - the sleep curve setting under Sleep mode by DIY:
Sleep3 - the sleep curve setting under Sleep mode by DIY could be inquired:
The user could accord to sleep curve setting method to inquire the presetting sleep
status, but do not change the tem-
curve, enter into user individuation sleep setting
perature, press "Turbo" button directly for confirmation.
Note: In the above presetting or enquiry procedure, if continuously within10s, there
will be automatically quit
is no button pressed, the sleep curve setting status
and resume to display the original displaying. In the presetting or enquiry pr-
"Mode" button, "Timer" button or "Sleep"
ocedure, press "ON/OFF" button,
button, the sleep curve setting or enquiry status will quit similarly.
up, the temperature will decrease 1
Ƈ
in every hour, after 3
Ƈ
decreased, this temperature will be maintained.
(4) Under the initial presetting temperature 28
Ƈ
-30
Ƈ
, after Sleep function started
at this time, the time of remote
ters into user individuation sleep setting status,
controller will display "1hour", the setting temperature "88" will display the corr-
last setting sleep curve and blink (The first entering
esponding temperature of
will display according to the initial curve setting value of original factory);
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote controller en-
after adjusted, press "Trubo" button for confirmation;
(2) Adjust "+" and "-" button, could change the corresponding setting temperature,
"8hours"), the place of se-
remote controller, (that are "2hours" or "3hours" or
tting temperature "88" will display the corresponding temperature of last setting sleep curve and blink;
(3) At this time, 1hour will be automatically increased at the timer postion on the
controller will resume the
sleep curve setting finished, at this time, the remote
original timer display; temperature display will resume to original setting tem- perature.
(4) Repeat the above step (2)~(3) operation, until 8hours temperature setting finished,
Introduction for special function
About AUTO RUN
When AUTO RUN mode is selected,
the unit will be in accordance with the room temp.
automatically to select the suitable running method and to make ambient comfortable.
About turbo function
If start this function, the unit will run at super-high fan speed to cool or heat quickly so
approachs the preset temp. as soon as possible.
that the ambient temp. approachs the preset temp.
About lock
Press + and - buttons simultaneously to lock or unlock the keyboard. If the remote co-
in which case, press any button,
ntroller is locked, the icon will be displayed on it,
the mark will flicker for three times. If the keyboard is unlocked, the mark will disappear.
About swing up and down
1. Press swing up and down button continuously more than 2s, the m ain unit will swing
the button, the unit will stop swing
backand forth from up to down , and then loosen
and present position of guide louver will be kept immediately.
2. Under swing up and down mode, when the status is switched from off to , if press
status directly; If press this button
this button again 2s later, status will switch to off
again within 2s, the change of swing status will also depend on the circulation seque-
nce stated above.
About swing left and right
1. Press swing left and right button continuously more than 2s, the main unit will swing
button, the unit will stop swing
back and forth from left to right, and then loosen the
and present position of guide louver will be kept immediately.
2. Under swing left and right mode, when the status is switched from off to , if press
status directly; if press this button
this button again 2s later, status will switch to off
again within 2s, the change of swing status will also depend on the circulation sequ-ence stated above.
About switch between Fahrenheit and Centigrade
Under status of unit off, press MODE and - buttons simultaneously to switch
Ƈ
and
Ɖ
.
Combination of "TEMP" and "CLOCK" buttons:
About Energy - saving Function
Press “TEMP” and “CLOCK” simultaneously in COOL mode to start energy-saving fun-
“SE”. Repeat the operation to quit
ction. Nixie tube on the remote controller displays
the function.
Combination of "TEMP" and "CLOCK" buttons:
About 8
Ƈ
Heating Function
Press “TEMP” and “CLOCK” simultaneously in HEAT mode to start 8
Ƈ
Heating Function
Nixie tube on the remote controller displays “ ” and a sele cted temperature of “8
Ƈ
”.
(46
Ɖ
if Fahrenheit is adopted). Repeat the operation to quit the function.