Operating Procedures / Photos
Disassemble Capillary
Unsolder the weld spots of capillary,valve and outlet
tube of condenser to remove the capillary.Prevent
welding slag from blocking the capillary.
Capillary
Disassemble Compressor
Unsolder the pipeline connecting the compressor,
and then unscrew the 3 foot-nuts fixing conpressor
to remove it.
Foot-nut