14
Technical Information
Service Manual
4. Refrigerant System Diagram
&RQQHFWLRQSLSHVSHFL¿FDWLRQ
Liquid pipe:1/4" (6mm)
Gas pipe:1/2" (12mm)18K
Gas pipe:5/8" (16mm)24K
Indoor unit
Outdoor unit
COOLING
HEATING
4-Way valve
Discharge
Suction
Heat
exchanger
(evaporator)
Heat
exchanger
(condenser)
Valve
Valve
Liquid pipe
side
Gas pipe
side
Strainer
Strainer
Capillary