background image

37

37

Ins

tal

lat

ion

 de

 l'u

nité

 in

tér

ieu

re

Avi

s:

•F

aite

s a

tte

ntio

n à

 la

 po

uss

ièr

e e

t p

ren

ez 

les

 pr

éca

utio

ns 

néc

ess

aire

s lo

rsq

ue 

vou

s

per

cez

 le

 tro

u.

•V

ous

 de

vez

 vo

us 

pro

cur

er l

es 

che

ville

en 

pla

stiq

ue 

qui

 ne

 so

nt p

as 

fou

rni

es.

1.L

e tu

yau

 pe

ut ê

tre

 di

rig

é v

ers

 la

 

dro

ite

, l'a

rriè

re-

dro

ite

, la

 ga

uch

e o

u

l'ar

riè

re-

gau

che

.

1.A

lig

nez

 l'u

nio

n d

u tu

yau

 av

ec 

l'or

ific

e é

vas

é c

orre

spo

nda

nt.

2.V

iss

ez 

l’é

cro

u-ra

cco

rd 

à la

 m

ain

.

3.S

erre

z l'é

cro

u-ra

cco

rd 

à l’a

ide

 de

 la

 clé

 po

ur c

ont

re-

écr

ou 

et d

e la

 clé

 

dyn

am

om

étri

que

 et

 ap

pliq

uer

 la

 fo

rce

 de

 to

rsio

n s

elo

n le

 ta

ble

au 

de 

la 

pag

e s

uiva

nte

.

2.L

ors

que

 vo

us a

ure

z d

écid

é o

ù ir

a

le 

tuy

au 

(ga

uch

e o

u d

roit

e), 

ass

u-

rez

-vo

us d

e fa

ire

 un

 tro

u d

u cô

équ

iva

len

t d

ans

 le 

bas

 du

 bo

îtie

r.

 

 

 

 

Ind

oor

5-1

0

out

doo

r

/

lef

t

rear left

right

rea

r ri

ght

 

 

lef

t

rig

ht

 

 

 

 

 

 

union

 nu

t

pip

e jo

int

pip

e

Int

érie

ur

Ext

érie

ur

dro

ite

gau

che

arri

ère

-dr

oite

arri

ère

-ga

uch

e

gau

che

dro

it

cou

pur

e

du 

tro

u

uni

on 

du 

tuy

au

écr

ou-

rac

cor

d

tuy

au

Installation of the indoor unit

Step Four: outlet pipe

Step Five: connect the pipe of indoor unit

Note:

• Pay attention to dust prevention and

take relevant safety measures when

opening the hole.

• The plastic expansion particles are

not provided and should be bought

locally.

1.The pipe can be led out in the

direction of right, rear right, left or

rear left.

1.Aim the pipe joint at the corres-

ponding bell mouth.

2.Pretighten the union nut with 

hand.

3.Adjust the torque force by referring to the following sheet. Place the 

open-end wrench on the pipe joint and place the torque wrench on the 

union nut. Tighten the union nut with torque wrench.

2. When select leading out the pipe

from left or right, please cut off 

the corresponding hole on the 

bottom case.

 

 

 

 

Indoor

5-10

outdoor

/

left

rear left

right

rear right

 

 

left

right

 

 

 

 

 

 

union nut

pipe joint

pipe

Indoor

Outdoor

right

left

rear right

rear left

left

right

cut off

the hole

pipe joint

union nut

pipe

éta

pe 

4: l

e tu

yau

 de

 so

rtie

éta

pe 

5:  

con

nec

tez

 le

 tu

yau

 de

 l'u

nité

 in

tér

ieu

re

00724_Owner's manual U-Crown_Mise en page 1  15-06-29  09:42  Page42

Summary of Contents for GWH09UC-D3DNA4AGWH12UC-D3DNA4AGWH18UC-D3DNA4A

Page 1: ...for choosing our Air Conditioner Please read this owner s manual carefully before operating the unit and keep it for future reference 00724 25 06 2015 Copyright GREE Canada 2015 GWH09UC D3DNA4A GWH12U...

Page 2: ......

Page 3: ...the unit Matching is not needed anymore once it is done During matching please keep the remote control and air conditioner under standby status When the signal of the remote control can t be received...

Page 4: ...llation 34 Selection of installation location 34 Requirements for electric connection 35 Installation Installation of indoor unit 36 Vacuum pumping 41 Leakage detection 41 Check after installation 42...

Page 5: ...18 Fonctionnement d urgence 26 Entretien Nettoyage et entretien 26 D faillances Analyse des d faillances 29 Instructions d installation Sch ma des dimensions d installation 33 Outils requis pour l in...

Page 6: ...tenance shall not be made by children Do not connect air conditioner to multi purpose socket Otherwise it may cause fire hazard Do disconnect power supply when cleaning air conditioner Otherwise it ma...

Page 7: ...off burning smell Indoor unit is leaking 1 Pr cautions d usage AVERTISSEMENT Utilisation et entretien Cet appareil peut tre utilis par des enfants g s de 8 ans et plus ou par des personnes capacit men...

Page 8: ...tion switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring Air Conditioner should be properly grounded Incorrect grounding may cause electric shock Make s...

Page 9: ...e requirement of NEC and CEC by authorized personnel only The air conditioner is a first class electric appliance It must be properly grounded with specialized grounding device by a professio nal Plea...

Page 10: ...ay cause personal injury or damage Select a location which is out of reach for children and far away from animals or plants If it is unavoidable please add a fence around the outdoor unit for safety p...

Page 11: ...in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interfe rence will not occur in a particular installation If this equipmen...

Page 12: ...d environment The antenna s used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conj...

Page 13: ...ts name Panel Filter Air outlet Air inlet Temp display Display Power wire Power Remote control Horizontal louver Indoor Unit NOTICE Actual product may be different from above graphics please refer to...

Page 14: ...n WIFI button Up down swing button Buttons on Remote Control Buttons on Remote Control Operation mode Auto mode Set fan speed Send signal Battery power Humidity functions Temp display type Healthy mod...

Page 15: ...y with models Pressing or button once increase or decrease set temperature by 0 5 C Holding or button the set temperature on remote control will change quickly On releasing the button after setting is...

Page 16: ...ar user when this function is set Do not put the remote control near an object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature Under simple swing mode...

Page 17: ...speed Press button to adjust fan blowing angle When selecting heating mode the air conditioner operates under heat mode Press or button to adjust set temperature Press FAN button to adjust fan speed...

Page 18: ...required time Press T OFF to confirm it The word OFF will stop blinking icon resumes displaying To cancel T OFF under the condition that T OFF is started up press T OFF button to cancel it Note Under...

Page 19: ...cularly as below HUMDITY HEALTH BUTTON 12 X FAN BUTTON 13 AIR BUTTON 14 LIGHT BUTTON 15 SLEEP BUTTON 16 INTELLIGENT INTELLIGENT cancel c cancel CANCEL Introduction for buttons on remote control Press...

Page 20: ...nd step 3 until 8 hour temperature setting is finished then the sleep curve is set successfully After that remote control will resume displaying the original timer time and temperature zone will resum...

Page 21: ...con will flick three times If the keyboard is unlocked the icon will disappear Under OFF status press MODE and buttons simultaneously to switch C and F ABOUT AUTO RUN ABOUT LOCK SWITCHING BETWEEN FAHR...

Page 22: ...When you don t use the remote control for a long time please take out the batteries If the display on the remote control is fuzzy or there s no display please replace the batteries 1 Press the back s...

Page 23: ...omputers maximum and it can operate only on short distance 1 Install G Life on your smart phone tablet PC Method 1 Enter Gree official website to download http www gree com english downloadcenter ihom...

Page 24: ...on is turned on 3 Enter the WiFi setting of your phone and search for the wireless network named gree xxxxxxxx Take gree E9D1 as an example Connect the network 4 Input the original password 12345 to c...

Page 25: ...dialog box to enter into Network Setting to modify network name e g gree my home and password refer to the attachment safe mode and password instruction 7 After modifying name and password click it t...

Page 26: ...he WiFi module is successfully reset Attention operation of the buttons is only effective in 2 minutes Analysis of common network setting failure if short distance control fails please check the follo...

Page 27: ...e control for the detailed operation 2 Temperature It is used for setting temperature Set the indoor temperature according to your requirement 3 Fan Speed It is used for setting fan speed Under coolin...

Page 28: ...s Please refer to the remote control section for the function instruction Among that Purify Humidify Air exchange functions can be set through equipping with special devices E heater is not available...

Page 29: ...low position button and the user can adjust the fan blowing area through moving the icon of air conditioner left and right according to the actual installation position of the unit User can move the p...

Page 30: ...ustment range varies with models and is function of the indoor unit Power saving After energy saving navigation mode is turned on the air conditioner will automatically detect indoor and outdoor tempe...

Page 31: ...uxiliary button to turn on or turn off the air conditioner When the air conditioner is turned on it will operate under auto mode Turn off the air conditioner and disconnect the power before cleaning t...

Page 32: ...re cleaning your main filter check if there is a spe cial filter attached to it rectangular shape as illustrated on the following page p 28 take it out and clean it separately where applicable and as...

Page 33: ...Ion Catechin and Antimites properties this multi function filter can i sterilize 99 of bacteria by suppressing proliferation of mold bacteria mites etc inhibiting the causes of allergies and unpleasa...

Page 34: ...ich is normal After reaching set temperature indoor unit will stop blowing out air Eliminate obstacles Cut the power supply off and put the power back after about 3min and then turn on the unit again...

Page 35: ...dirty Set temperature is in proper range Doors and windows are open Close doors and windows Adjust temperature to proper range Clean the filter Wait until the voltage resumes to normal Your required t...

Page 36: ...ain Outdoor unit emits vapor Heating mode is turned on During defrosting under heating mode it may produce vapor which is a normal Water flowing noise Has the air conditioner just been turned on and o...

Page 37: ...ied professionals for service It can be eliminated after restarting the unit If not please contact qualified professionals for service It can be eliminated after restarting the unit If not please cont...

Page 38: ...Installation dimension diagram Space to the ceilling At least 15cm At least 15cm At least 250cm At least 15cm At least 300cm Space to the obstruction Space to the floor Space to the wall Space to the...

Page 39: ...A place with high frequency devices such as welding machine medical equipment 3 A place near coast area 4 A place with oil or fumes in the air 5 A place with sulphurous gas 6 0ther places with special...

Page 40: ...through the power before finishing installation 7 The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube 8 The appliance shall be installed...

Page 41: ...g screws ST4 2X25TA and then check if the frame is firmly installed by pulling the frame If the plastic expansion particle is loose please drill another fixing hole nearby 1 Choose the position of pip...

Page 42: ...e joint at the corres ponding bell mouth 2 Pretighten the union nut with hand 3 Adjust the torque force by referring to the following sheet Place the open end wrench on the pipe joint and place the to...

Page 43: ...t pipe of indoor unit 2 Bind the joint with tape 1 Open the panel remove the screw on the wiring cover and then take down the cover Note Add insulating pipe in the indoor drain hose in order to preven...

Page 44: ...owing figure in order to avoid pressing the wire when closing the electric box cover 4 Put wiring cover back and then tighten the screw 5 Close the panel L2 S L1 green green red black yellow brown whi...

Page 45: ...indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the indoor unit is installed firmly and close to the wall 3 Bind the...

Page 46: ...ssure of manometer remains in 0 1 MPa If the pressure decreases there may be leakage 5 Remove the manometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Ti...

Page 47: ...pletely 1 Before test operation The client approves the air conditioner Specify the important notes on air conditioner to the client 2 Method of test operation Put through the power press ON OFF butto...

Page 48: ...and max rise difference Cooling capacity Max length of connection pipe Max rise difference 20 10 9000Btu h 2637W 20 10 12000Btu h 3516W 25 10 18000Btu h 5274W 24000Btu h 7032W Cooling capacity Max le...

Page 49: ...r unit throttle Diameter of connection pipe Liquid pipe mm Cooling only g m Cooling and heating g m Gas pipe mm Additional refrigerant charging amount for R410A 6 15 20 9 52 or 12 12 30 120 19 or 22 2...

Page 50: ...h expander F Inspection Check the quality of expanding port If there is any blemish expand the port again according to the steps above 6 6 35 1 4 Note A varies according to the diameter please refer t...

Reviews: