1. There should be no obstruction near air inlet .
2. Select a location where the condensation water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach for children.
5. The location should be able to withstand the weight of indoor unit and won't
increase noise and vibration.
6. The appliance must be installed 2.5m above floor.
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from fluorescent lamp.
Selection of installation location
Indoor unit
Basic requirement
Installing the unit in the following places maycause malfunction. If it is unavoidable,
please consult the local dealer:
1. The place with strong heat sources, vapors, flammable or explosive gas, or
volatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical
equipment).
as truck) or in the corrosive environment (such as chemical factory).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. The appliance shall not be installed in the laundry.
8. It’s not allowed to be installed on the unstable or motive base structure (such
`
Tools for installation
1 Level meter
2 Screw driver
3 Impact drill
4 Drill head
5 Pipe expander
6 Torque wrench
7 Open-end wrench
8 Pipe cutter
9 Leakage detector
10 Vacuum pump
11 Pressure meter
12 Universal meter
13 Inner hexagon spanner
14 Measuring tape
Note:
V Please contact the local agent for installation.