64
Removal Procedure
Steps
Procedure
16. Remove condenser and capillary
Remove the screws on condenser, unsolder the
spot weld (notice: before the soldering, release
the refrigerant completely) between capillary
and condenser, pull it outward and then remove
the condenser and capillary.
17. Remove gas valve and valve support
Remove the bolts used for fixing the gas valve
and valve support, and then the gas valve can
be removed; Twist off the screws used for
connecting the valve support and chassis, pull it
upward slightly and then remove the valve
support