)XQFWLRQDQG&RQWURO
SLEEP BUTTON
SLEE
P
●
●
Press this button, can select Sleep 1 ( ), Sleep 2 ( ),
Sleep 3 ( ) and cancel the Sleep, circulate between
these, after electrified, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool, Dehumidify modes: sleep status
after run for one hour , the main unit setting temperature will
increase 1
,setting temperature increased 2
, the unit will
run at this setting temperature; In Heat mode: sleep status after run
for one hour , the setting temperature will decrease 1
, 2
hours , setting temperature will decrease 2
, then the unit will
run at this setting temperature.
●
Sleep 2 is sleep mode 2, that is air conditioner will run according to
the presetting a group of sleep temperature curve.
In Cool mode:
(1) When setting the initial temperature 16-23
, after turned on
Sleep function, the temperature will be increased 1
in every hour,
after 3
the temperature will be maintained, after 7hours,
the temperature will be decreased 1
, after that the unit will keep on
running under this temperature;
(2) When setting the initial temperature 24
2 7
, after turned
on Sleep function, the temperature will be increased 1 in every hour ,
after 2
the temperature will be maintained, after 7hours,
the temperature will be decreased 1
, after that the unit will
keep on running under this temperature;
(3) When setting the initial temperature 28
29
, after turned
on Sleep function, the temperature will be increased 1
in every
hour, after 1
the temperature will be maintained, after 7hours ,
the temperature will be decreased 1
, after that the unit will
keep on running under this temperature;
(4) When setting the initial temperature 30
, under this temper-
ature setting, after 7hours, the temperature will be decreased
1
, after that the unit will keep on running under this temperature;
In Heat mode:
(1) Under the initial presetting temperature 16
, it will run under
this setting temperature all along.
(2) Under the initial presetting temperature17
20
, after Sleep
function started up, the temperature will decrease 1
in every
hour, after 1
decreased, this temperature will be maintained.