background image

31

31

Vér

ific

atio

n a

prè

s l'

ins

tal

lat

ion

À v

érif

ier

 ap

rès

 l'i

nst

alla

tio

n

• F

aite

s le

s v

érif

ica

tio

ns 

sui

van

tes

 ap

rès

 av

oir 

com

plé

té 

l'in

sta

lla

tio

n.

Poi

nts

 à 

vér

ifie

r

Déf

ect

uos

ité

s p

oss

ibl

es

L'ap

par

eil a

-t'il

 ét

é s

olid

em

ent

 in

sta

llé

 ?

Ave

z-v

ous

 vé

rifié

 s'i

l n

'y 

a p

as 

de 

fui

te 

?

Les

 tu

yau

x d

e l'a

ppa

rei

l s

ont

-ils

 bi

en

iso

lés

 ?

L'ea

u e

st-e

lle

 dr

ain

ée 

cor

rec

tem

ent

 ?

La 

ten

sion

 co

rre

spo

nd-

t'el

le 

à la

 te

nsio

nom

ina

le 

qui 

figu

re 

sur

 la 

plaq

ue 

sign

alét

iqu

e?

Les

 fils

 él

ect

riq

ues

 et

 le

s tu

yau

x s

ont

-ils

rac

cor

dés

 co

rre

cte

men

t ?

L'ap

par

eil a

-t-i

l é

té 

mis 

à la

 te

rre

 

cor

rec

tem

ent

 ?

Le 

fil d

ʼal

im

ent

atio

n e

st-i

l c

onf

orm

e a

ux

nor

mes

 sp

écif

ées

 ?

Est

-ce

 qu

e l'e

ntré

e o

u la

 so

rtie

 d'a

ir s

ont

obs

tru

ées

 ?

L'ap

par

eil a

-t-il

 été

 ne

ttoy

é et

 dé

bar

ras

sé d

e la

pou

ssiè

re e

t de

s dé

tritu

s fa

its 

dur

ant 

l'in

stal

lati

on ?

Les

 va

lve

s so

nt-e

lles

 co

mplè

tem

ent

 ou

ver

tes

?

1.A

van

t le

 te

st d

e fo

nct

ion

nem

ent

• V

érif

ier

 si 

le 

clie

nt e

st s

atis

fait

.  

• I

nfo

rm

ez l

e cl

ien

t su

r le

s p

oint

s im

por

tan

ts d

e l'a

ppa

reil

.

2.F

aire

 le

 te

st d

e fo

nct

ion

nem

ent

• M

ettr

e le

 co

ura

nt é

lec

triq

ue 

et  

app

uye

z su

r la

 to

uch

e 'O

N/O

FF'

 de

 la 

télé

com

man

de 

pou

r d

ém

arre

r l'a

ppa

reil

.

• A

ppu

yez

 su

r la

 to

uch

e 'M

ODE

' p

our

 ch

oisi

r A

UTO

, C

OO

L, D

RY,

 FA

N e

t H

EAT

 

et a

ins

i vé

rifie

r si

 l'a

ppa

reil

 fo

ncti

onn

e n

orm

alem

ent

 ou

 no

n.

• S

i la

 te

mpé

rat

ure

 am

bian

te 

est 

en 

bas

 de

 16

°C,

 le 

clim

atis

eur

 ne

 fo

ncti

onn

era

 pa

s.   

Cela

 pe

ut a

ffe

cte

r le

 re

nde

men

t d

l'ap

par

eil (

en 

clim

atis

atio

n o

u ch

auf

fag

e).

Cel

a p

eut

 ca

use

r u

n m

auv

ais 

fon

ctio

n-

nem

ent

 ou

 en

dom

mag

er l

es 

piè

ces

.

Cela

 pe

ut a

ffe

cte

r le

 re

nde

men

t d

e la

 

clim

atis

atio

n o

u d

u ch

auf

fag

e.

Cel

a p

eut

 ca

use

r u

n m

auv

ais 

fon

ctio

n-

nem

ent

 ou

 en

dom

mag

er d

es 

piè

ces

.

Cel

a p

eut

 en

tra

îne

r u

ne 

disp

ers

ion

 

éle

ctri

que

.

Cel

a p

eut

 ca

use

r u

n m

auv

ais 

fon

ctio

n-

nem

ent

 ou

 en

dom

mag

er l

es 

piè

ces

.

Cel

a p

eut

 ca

use

r u

n m

auv

ais 

fon

ctio

n-

nem

ent

 ou

 en

dom

mag

er l

es 

piè

ces

.

Cel

a p

eut

 fa

ire

 de

 la

 co

nde

nsa

tio

n o

u

l'ap

par

eil p

eut

 dé

gou

tte

r.

Cel

a p

eut

 fa

ire

 de

 la

 co

nde

nsa

tio

n o

u

l'ap

par

eil p

eut

 dé

gou

tte

r.

Une

 fu

ite

 ris

que

 d'a

ffe

cte

r le

 re

nde

men

t

de 

la 

clim

atis

atio

n o

u d

u c

hau

ffa

ge.

L'ap

par

eil p

eut

 to

mbe

r, v

ibr

er o

u ê

tre

 br

uya

nt.

Check after installation

Check after installation

• Check the following after finishing installation.

Items to be checked

Possible malfunction

1. Preparation of test operation

•  The client approves the air conditioner.

•  Specify the important features of the air conditioner to the client.

2. Method of test operation

•  Put through the power, press ON/OFF button on the remote control to start

operation.

•  Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check

whether the operation is normal or not.

•  If the ambient temperature is lower than 16°C , the air conditioner can't

start cooling.

Has the unit been installed solidly?
Have you done the refrigerant leakage

test?

Is heat insulation of pipeline sufficient?

Is water drained well?

Is the voltage of power supply 

according to the voltage marked on the

nameplate?
Is electric wiring and pipeline installed

correctly?
Is the unit grounded securely?
Does the power wire follow the 

specification?
Is there any obstruction in the air inlet

and outlet?
The dust and sundries caused during

installation are removed?
The gas valve and liquid valve of

connection pipe are open completely?

It may cause insufficient cooling

(heating) capacity.

It may cause malfunction or damaging

the parts.

It may cause insufficient cooling

(heating) capacity.

It may cause malfunction or damaging

the parts.

It may cause electric leakage.

It may cause malfunction or damaging

the parts.

It may cause malfunction or damaging

the parts.

It may cause condensation and water

dripping.

It may cause condensation and water

dripping.

It may cause insufficient cooling 

(heating) capacity.

The unit may drop, shake or emit noise.

00762_BUILDER 15SEER 9K12K18K24K_Mise en page 1  16-06-02  14:49  Page35

Summary of Contents for GWC09MB-D3DNK Series

Page 1: ...ase read this owner s manual carefully before operating the unit and keep it for future reference 00762_30 05 2016 Copyright GREE Canada 2016 GWC09MB D3DN K GWC12MB D3DN K GWC18MC D3DN K GWC24MD D3DN...

Page 2: ......

Page 3: ...34 Selection of installation location 34 Requirements for electric connection 35 Installation Installation of indoor unit 36 Installation of outdoor unit Vacuum pumping 41 Leakage detection 41 Check...

Page 4: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Page 5: ...ade by children Do not connect air conditioner to multi purpose socket Otherwise it may cause fire hazard Do disconnect power supply when cleaning air conditioner Otherwise it may cause electric shock...

Page 6: ...control otherwise the remote control may no longer operate When below phenomenon occurs please turn off air conditioner and disconnect power immediately and then contact the dealer or qualified profes...

Page 7: ...n switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring Air Conditioner should be properly grounded Incorrect grounding may cause electric shock Make sure...

Page 8: ...nce with the requirement of NEC and CEC by authorized personnel only The air conditioner is a first class electric appliance It must be properly grounded with specialized grounding device by a profess...

Page 9: ...s WARNING If you need to relocate the air conditioner to another place only a qualified person can perform the work Otherwise it may cause personal injury or damage Select a location which is out of r...

Page 10: ...ator Temp indicator Cooling indicator Power indicator Receiver window Diplay Horizontal louver Indoor Unit NOTICE Actual product may be different from above graphics please refer to actual products Re...

Page 11: ...4 6 2 5 7 ON OFF button 2 MODE button 3 button 4 FAN button 5 SWING button 6 SLEEP button 7 TIMER button Timer on Timer off Sending signal swing operation auto operation cool operation dry operation...

Page 12: ...ure by 1 F C Hold or button for 2s set temperature on remote control will change quickly Release the button after your required set temperature is reached When setting Timer On or Timer Off press or b...

Page 13: ...utton for 2s time will change quickly Release the button after your required set time is reached Then press TIMER button to confirm it T OFF and H icon will stop blinking When unit is off press this b...

Page 14: ...ion for buttons on remote controller Function introduction for combination buttons Note Range of time setting is 0 5 24h The interval between two motions can t exceed 5s otherwise the remote controlle...

Page 15: ...emove cover of battery box During operation point the remote control signal sender at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than...

Page 16: ...clean the air conditioner Clean surface of indoor unit If the remote control is lost or damaged please use auxiliary button to turn on or turn off the air conditioner As shown in the figure open the p...

Page 17: ...ry Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard 2 Clean filter Use a vacuum or water to clean the filter When the filter is very dirty use water below 45 c to cl...

Page 18: ...overy 1 Many packing materials are recyclable Please dispose of them in appropriate recycling bin 2 If you want to get rid of the air conditioner please contact local dealer or recycling service cente...

Page 19: ...been turned on which is normal After reaching set temperature indoor unit will stop blowing out air Eliminate obstacles Cut the power supply off and put the power back after about 3min and then turn...

Page 20: ...temperature is in proper range Doors and windows are open Close doors and windows Adjust temperature to proper range Clean the filter Wait until the voltage resumes to normal Your required temperature...

Page 21: ...d then turn on the unit again Outdoor unit emits vapor Heating mode is turned on During defrosting under heating mode it may produce vapor which is a normal Water flowing noise Has the air conditioner...

Page 22: ...nusual sound during operation Air switch trips off frequently Air conditioner generates a burning smell Indoor unit is leaking ATTENTION Do not repair or refit the air conditioner by yourself If the a...

Page 23: ...ll At least 15cm At least 15cm At least 250cm Space to the floor At least 300cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the obstruction Drainage pipe Space...

Page 24: ...allation Installing the unit in the following places may cause malfunction If it is unavoidable please consult your local dealer or a certified technician 1 A place with strong heat sources vapors fla...

Page 25: ...circuit will be high please keep the interconnection cable away from the copper tube 8 The appliance shall be installed in accordance with national wiring regulations 9 Installation must be performed...

Page 26: ...ll with tapping screws ST4 2X25TA and then check if the frame is firmly installed by pulling the frame If the plastic expansion particle is loose please drill another fixing hole nearby 1 Choose the p...

Page 27: ...e plastic expansion particles are not provided and should be bought locally 1 The pipe can be led out in the direction of right rear right left or rear left 1 Aim the pipe joint at the corres ponding...

Page 28: ...2 Bind the joint with tape 1 Open the panel remove the screw on the wiring cover and then take down the cover 30 40 4 open end wrench union nut pipe torque wrench indoor pipe outlet pipe drain hose ta...

Page 29: ...the screw and then fix the power connection wire with wire clip After finishing wiring clamp the grounding wire yellow green wire into the wire crossing groove as shown in the following figure in ord...

Page 30: ...all pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the...

Page 31: ...protective measures when installing the outdoor unit Make sure the support can withstand at least four times the unit weight The outdoor unit should be installed at least 3cm above the floor in order...

Page 32: ...to the wiring terminal according to the color fix themwith screws Note the wiring board is for reference only please refer to the actual one 3 Pretighten the union nut with hand 4 Tighten the union nu...

Page 33: ...om in order to prevent rain from getting into the room The through wall height of drain hose shouldn t be higher than the outlet pipe hole of indoor unit The water outlet can t be placed in water in o...

Page 34: ...remains in 0 1 MPa If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw c...

Page 35: ...nsulation of pipeline sufficient Is water drained well Is the voltage of power supply according to the voltage marked on the nameplate Is electric wiring and pipeline installed correctly Is the unit g...

Page 36: ...capacity Max length of connection pipe Max rise difference 25 10 30 10 30 20 28000Btu h 8204W 36000Btu h 10548W 30 20 42000Btu h 12306W 30 20 48000Btu h 14064W u 4 Additional regrigerant liquid and r...

Page 37: ...r unit throttle Diameter of connection pipe Liquid pipe mm Cooling only g m Cooling and heating g m Gas pipe mm Additional refrigerant charging amount for R410A 6 15 20 9 52 or 12 12 30 120 19 or 22 2...

Page 38: ...th expander F Inspection Check the quality of expanding port If there is any blemish expand the port again according to the steps above 6 6 35 1 4 Note A varies according to the diameter please refer...

Reviews: